SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-146812"
 

Sökning: id:"swepub:oai:DiVA.org:kth-146812" > Comparison of propa...

Comparison of propagation-and grating-based x-ray phase-contrast imaging techniques with a liquid-metal-jet source

Zhou, Tunhe (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Lundström, Ulf (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Thüring, T. (författare)
visa fler...
Rutishauser, S. (författare)
Larsson, Daniel H. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Stampanoni, M. (författare)
David, C. (författare)
Hertz, Hans M. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Burvall, Anna (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2014
2014
Engelska.
Ingår i: Medical Imaging 2014. - : SPIE - International Society for Optical Engineering. - 9780819498267 ; , s. 903353-
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • X-ray phase-contrast imaging has been developed as an alternative to conventional absorption imaging, partly for its dose advantage over absorption imaging at high resolution. Grating-based imaging (GBI) and propagation-based imaging (PBI) are two phase-contrast techniques used with polychromatic laboratory sources. We compare the two methods by experiments and simulations with respect to required dose. A simulation method based on the projection approximation is designed and verified with experiments. A comparison based on simulations of the doses required for detection of an object with respect to its diameter is presented, showing that for monochromatic radiation, there is a dose advantage for PBI for small features but an advantage for GBI at larger features. However, GBI suffers more from the introduction of polychromatic radiation, in this case so much that PBI gives lower dose for all investigated feature sizes. Furthermore, we present and compare experimental images of biomedical samples. While those support the dose advantage of PBI, they also highlight the GBI advantage of quantitative reconstruction of multimaterial samples. For all experiments a liquid-metal-jet source was used. Liquid-metal-jet sources are a promising option for laboratory-based phase-contrast imaging due to the relatively high brightness and small spot size.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

grating-based
phase-contrast
propagation-based
X-ray imaging

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy