Numerical investigation of heat transfer characteristics in utility boilers of oxy-coal combustion

Hu, Yukun (författare)
KTH,Energiprocesser,Royal Institute of Technology, Sweden
Li, Hailong (författare)
Mälardalens högskola,Framtidens energi
Yan, Jinyue (författare)
Mälardalens högskola,KTH,Energiprocesser,Malardalen Univ, Sch Sustainable Dev Soc & Technol, SE-72123 Vasteras, Sweden,Framtidens energi,Royal Institute of Technology, Sweden
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Applied Energy. - : Elsevier BV. - 0306-2619 .- 1872-9118. ; 130, s. 543-551
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Oxy-coal combustion has different flue gas composition from the conventional air-coal combustion. The different composition further results in different properties, such as the absorption coefficient, emissivity, and density, which can directly affect the heat transfer in both radiation and convection zones of utility boilers. This paper numerically studied a utility boiler of oxy-coal combustion and compares with air-coal combustion in terms of flame profile and heat transferred through boiler side walls in order to understand the effects of different operating conditions on oxy-coal boiler retrofitting and design. Based on the results, it was found that around 33 vol% of effective O-2 concentration ([O-2](effective)) the highest flame temperature and total heat transferred through boiler side walls in the oxy-coal combustion case match to those in the air-coal combustion case most; therefore, the 33 vol% of [O-2](effective) could result in the minimal change for the oxy-coal combustion retrofitting of the existing boiler. In addition, the increase of the moisture content in the flue gas has little impact on the flame temperature, but results in a higher surface incident radiation on boiler side walls. The area of heat exchangers in the boiler was also investigated regarding retrofitting. If boiler operates under a higher [O-2](effective), to rebalance the load of each heat exchanger in the boiler, the feed water temperature after economizer can be reduced or part of superheating surfaces can be moved into the radiation zone to replace part of the evaporators.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Nyckelord

Oxy-coal combustion
Boiler
Radiation
Heat transfer
Wet recycle

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hu, Yukun
Li, Hailong
Yan, Jinyue
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Annan teknik
Artiklar i publikationen
Applied Energy
Av lärosätet
Kungliga Tekniska Högskolan
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy