Effects of ultrasound contrast agents on Doppler tissue velocity estimation

Ressner, Marcus, 1967- (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Brodin, Lars-Åke (författare)
Karolinska Institutet,KTH,Medicinsk teknik,The Royal Institute of Technology, Stockholm, Sweden
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund Institute of Technology, Lund, Sweden
visa fler...
Hoff, L. (författare)
Vestfold University College, Noway
Ask, Per, 1950- (författare)
Linköpings universitet,Tekniska högskolan,Fysiologisk mätteknik
Janerot-Sjöberg, Birgitta, 1958- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Klinisk fysiologi,Fysiologiska kliniken
visa färre...
 (creator_code:org_t)
Elsevier BV, 2006
2006
Engelska.
Ingår i: Journal of the American Society of Echocardiography. - : Elsevier BV. - 0894-7317 .- 1097-6795. ; 19:2, s. 154-164
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the myocardium in a single examination. The purpose of this study was to establish how the presence of ultrasound contrast agent (UCA) affects measurements of Doppler tissue velocities in vivo and in vitro. We performed echocardiography in 12 patients with ischemic heart disease before and immediately after a slow intravenous infusion of the UCA Optison, using color Doppler tissue imaging to examine the effect of contrast agents in vivo. The myocardial peak systolic velocities and their integrals were analyzed in digitally stored cineloops before and after contrast administration. To distinguish between methodologic and physiologic factors affecting the measurement of tissue velocity in vitro, experiments with a rotating disk and a flow cone phantom were also carried out for the 3 contrast agents: Optison, Sonovue, and Sonazoid. in vivo results show that the values for peak systolic velocity increased by about 10% during contrast infusion, from mean 5.2 +/- 1.8 to 5.7 +/- 2.3 cm/s (P = .02, 95% confidence interval 2%-16%). The increase in myocardial peak systolic velocities was verified in experimental models in which the UCA increased the estimated mean velocity in the order of 5% to 20% for the motion interval of 5 to 7 cm/s, corresponding to the myocardial velocities studied in vivo. The response was similar for all 3 contrast agents and was not affected by moderate variations in concentration of the agent. We have shown that the presence UCA will affect Doppler tissue measurements in vivo and in vitro. The observed bias is presumed to be an effect of harmonic signal contribution from rupturing contrast agent microbubbles and does not indicate biologic or physiologic effects.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

acute-myocardial-infarction
blood-flow
in-vitro
mode images
microbubbles
echocardiography
destruction
growth
shift
vivo
MEDICINE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy