- The uterine cervix has to provide mechanical resistance to ensure a normal development of the fetus. This is guaranteed by the composition of its extracellular matrix, which functions as a fiber-reinforced composite. At term a complex remodeling process allows the cervical canal to open for birth. This remodeling is achieved by changes in the quality and quantity of collagen fibers and ground substance and their interplay, which influences the biomechanical behavior of the cervix but also contributes to pathologic conditions such as cervical incompetence (CI). We start by reviewing the anatomy and histological composition of the human cervix, and discuss its physiologic function and pathologic condition in pregnancy including biomechanical aspects. Established diagnostic methods on the cervix (palpation, endovaginal ultrasound) used in clinics as well as methods for assessment of cervical consistency (light-induced fluorescence, electrical current, and impedance) are discussed. We show the first clinical application of an aspiration device, which allows in vivo testing of the biomechanical properties of the cervix with the aim to establish the physiological biomechanical changes throughout gestation and to detect pregnant women at risk for CI. In a pilot study on nonpregnant cervices before and after hysterectomy we found no considerable difference in the biomechanical response between in vivo and ex vivo. An outlook on further clinical applications during pregnancy is presented.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Annan medicin och hälsovetenskap (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Other Medical and Health Sciences (hsv//eng)
Nyckelord
- Aspiration device
- Biomechanical properties
- In vivo experiment
- Remodeling in pregnancy
- Uterine cervix
Publikations- och innehållstyp