SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-157026"
 

Sökning: id:"swepub:oai:DiVA.org:kth-157026" > Energy-resolved CT ...

Energy-resolved CT imaging with a photon-counting silicon-strip detector

Persson, Mats (författare)
KTH,Medicinsk bildfysik
Huber, Ben (författare)
KTH,Medicinsk bildfysik
Karlsson, Staffan (författare)
KTH,Medicinsk bildfysik
visa fler...
Liu, Xuejin (författare)
KTH,Medicinsk bildfysik
Chen, Han (författare)
KTH,Medicinsk bildfysik
Xu, Cheng (författare)
KTH,Medicinsk bildfysik
Yveborg, Moa (författare)
KTH,Medicinsk bildfysik
Bornefalk, Hans (författare)
KTH,Medicinsk bildfysik
Danielsson, Mats (författare)
KTH,Medicinsk bildfysik
visa färre...
 (creator_code:org_t)
2014-10-20
2014
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 59:22, s. 6709-6727
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Photon-counting detectors are promising candidates for use in the next generation of x-ray computed tomography (CT) scanners. Among the foreseen benefits are higher spatial resolution, better trade-off between noise and dose and energy discriminating capabilities. Silicon is an attractive detector material because of its low cost, mature manufacturing process and high hole mobility. However, it is sometimes overlooked for CT applications because of its low absorption efficiency and high fraction of Compton scatter. The purpose of this work is to demonstrate that silicon is a feasible material for CT detectors by showing energy-resolved CT images acquired with an 80 kVp x-ray tube spectrum using a photon-counting silicon-strip detector with eight energy thresholds developed in our group. We use a single detector module, consisting of a linear array of 50 0.5 x 0.4 mm detector elements, to image a phantom in a table-top lab setup. The phantom consists of a plastic cylinder with circular inserts containing water, fat and aqueous solutions of calcium, iodine and gadolinium, in different concentrations. By using basis material decomposition we obtain water, calcium, iodine and gadolinium basis images and demonstrate that these basis images can be used to separate the different materials in the inserts. We also show results showing that the detector has potential for quantitative measurements of substance concentrations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

photon counting
spectral CT
material decomposition
siliconstrip detector

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy