SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-157573"
 

Sökning: id:"swepub:oai:DiVA.org:kth-157573" > Point-of-Care Verti...

Point-of-Care Vertical Flow Allergen Microarray Assay : Proof of Concept

Chinnasamy, Thiruppathiraja (författare)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
Segerink, Loes I. (författare)
Nystrand, Mats (författare)
visa fler...
Gantelius, Jesper (författare)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
Andersson Svahn, Helene (författare)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
visa färre...
 (creator_code:org_t)
2014-09-01
2014
Engelska.
Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 60:9, s. 1209-1216
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Sophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of < 10 min before imaging and data analysis. METHOD: Affinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of <= 10 min. Microarray images were captured by a consumer-grade flatbed scanner. RESULTS: A sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was < 14%. The observed concordance with a clinical assay, Immuno-CAP, was R-2 = 0.89 (n = 31). CONCLUSIONS: In this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing.

Ämnesord

NATURVETENSKAP  -- Kemi -- Annan kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Other Chemistry Topics (hsv//eng)

Nyckelord

Allergens
Colorimetry
Gold
Humans
Immunoglobulin E
Metal Nanoparticles
Point-of-Care Systems
Protein Array Analysis
Reproducibility of Results
Sensitivity and Specificity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy