DNA separation and fluorescent detection in an optofluidic chip with sub-base-pair resolution

Pollnau, Markus (författare)
KTH,Material- och nanofysik,Univ Twente, Netherlands
Hammer, Manfred (författare)
Dongre, Chaitanya (författare)
visa fler...
Hoekstra, Hugo J. W. M. (författare)
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2015
2015
Engelska.
Ingår i: Microfluidics, BioMEMS, and Medical Microsystems XIII. - : SPIE - International Society for Optical Engineering. - 9781628414103
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • DNA sequencing in a lab-on-a-chip aims at providing cheap, high-speed analysis of low reagent volumes to, e.g., identify genomic deletions or insertions associated with genetic illnesses. Detecting single base-pair insertions/deletions from DNA fragments in the diagnostically relevant range of 150-1000 base-pairs requires a sizing accuracy of S < 10(-3). Here we demonstrate S = 4x10(-4). A microfluidic chip was post-processed by femtosecond-laser writing of an optical waveguide. 12 blue-labeled and 23 red-labeled DNA fragments were separated in size by capillary electrophoresis, each set excited by either of two lasers power-modulated at different frequencies, their fluorescence detected by a photomultiplier, and blue/red signals distinguished by Fourier analysis. Different calibration strategies were tested: a) use either set of DNA molecules as reference to calibrate the set-up and identify the base-pair sizes of the other set in the same flow experiment, thereby eliminating variations in temperature, wall-coating and sieving-gel conditions, and actuation voltages; b) use the same molecular set as reference and sample with the same fluorescence label, flown in consecutive experiments; c) perform cross-experiments based on different molecular sets with different labels, flown in consecutive experiments. From the results we conclude: Applying quadratic instead of linear fit functions improves the calibration accuracy. Blue-labeled molecules are separated with higher accuracy. The influence of dye label is higher than fluctuations between two experiments. Choosing a single, suitable dye label combined with reference calibration and sample investigation in consecutive experiments results in S = 4x10(-4), enabling detection of single base-pair insertion/deletion in a lab-on-a-chip.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Nyckelord

DNA separation
optofluidic chip
capillary electrophoresis
fluorescent detection
single base-pair insertion/deletion
sub-base-pair sizing accuracy

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Pollnau, Markus
Hammer, Manfred
Dongre, Chaitany ...
Hoekstra, Hugo J ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Annan teknik
Artiklar i publikationen
Microfluidics, B ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy