Reliability of a new instrument for measuring plantarflexor muscle strength
-
- Örtqvist, Maria (författare)
- Karolinska Institutet
-
- Gutierrez-Farewik, Elena M. (författare)
- Karolinska Institutet,KTH,Mekanik
-
- Farewik, Markus (författare)
- KTH
-
visa fler...
-
Jansson, Anna (författare)
-
- Bartonek, Åsa (författare)
- Karolinska Institutet
-
- Broström, Eva (författare)
- Karolinska Institutet
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2007
- 2007
- Engelska.
-
Ingår i: Archives of Physical Medicine and Rehabilitation. - : Elsevier BV. - 0003-9993 .- 1532-821X. ; 88:9, s. 1164-1170
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objectives: To test the reliability of a new muscle strength testing instrument (the Strength Measuring Chair [SMC]) designed to quantify isometric strength in the lower extremities, and to determine the agreement between the SMC and an isokinetic dynamometer (Biodex). Design: Isometric strength tests were performed in plantar-flexors with 2 different knee positions (60 degrees, 30 degrees). Measurements were taken at 3 different sessions. Setting: Strength testing laboratory. Participants: Twenty-three able-bodied adults and 15 able-bodied children. Interventions: Not applicable. Main Outcome Measure: Isometric plantarflexor strength. Results: The reliability of isometric strength measurements of plantarflexors taken in the SMC was excellent for both the adult and children groups (intraclass correlation coefficient range,.84-.87). A Bland-Altman 95% limit of agreement test showed no systematic variation in 3 of the 4 SMC test observations; systematic variation was only observed in the adult group at a knee position of 30 degrees. There was no systematic difference in the adult group between the SMC and the isokinetic dynamometer, but there was a systematic variation in the children's group. Conclusions: The SMC reliably measured isometric plantarflexor strength in the tested populations.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Nyckelord
- gastrocnemius muscle
- isometric contraction
- rehabilitation
- reproducibility of results
- soleus muscle
- hand-held dynamometry
- interrater reliability
- isokinetic dynamometer
- cerebral-palsy
- children
- torque
- knee
- activation
- arthritis
- velocity