SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-171566"
 

Sökning: id:"swepub:oai:DiVA.org:kth-171566" > Gradient-Based Enha...

Gradient-Based Enhancement of Tubular Structures in Medical Images

Moreno, Rodrigo, 1973- (författare)
Linköpings universitet,KTH,Medicinsk bildbehandling och visualisering,Linköping University,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,KTH Royal Institute of Technology
Smedby, Örjan, 1956- (författare)
Östergötlands Läns Landsting,Linköpings universitet,KTH,Medicinsk bildbehandling och visualisering,Linköping University,Avdelningen för radiologiska vetenskaper,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Röntgenkliniken i Linköping,Medicinska fakulteten,KTH Royal Institute of Technology
 (creator_code:org_t)
Elsevier, 2015
2015
Engelska.
Ingår i: Medical Image Analysis. - : Elsevier. - 1361-8415 .- 1361-8423. ; 26:1, s. 19-29
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Vesselness filters aim at enhancing tubular structures in medical images. The most popular vesselness filters are based on eigenanalyses of the Hessian matrix computed at different scales. However, Hessian-based methods have well-known limitations, most of them related to the use of second order derivatives. In this paper, we propose an alternative strategy in which ring-like patterns are sought in the local orientation distribution of the gradient. The method takes advantage of symmetry properties of ring-like patterns in the spherical harmonics domain. For bright vessels, gradients not pointing towards the center are filtered out from every local neighborhood in a first step. The opposite criterion is used for dark vessels. Afterwards, structuredness, evenness and uniformness measurements are computed from the power spectrum in spherical harmonics of both the original and the half-zeroed orientation distribution of the gradient. Finally, the features are combined into a single vesselness measurement. Alternatively, a structure tensor that is suitable for vesselness can be estimated before the analysis in spherical harmonics. The two proposed methods are called Ring Pattern Detector (RPD) and Filtered Structure Tensor (FST) respectively. Experimental results with computed tomography angiography data show that the proposed filters perform better compared to the state-of-the-art.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Vesselness
Structure Tensor
Spherical Harmonics
Medical Technology
Medicinsk teknologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy