A new technique for diagnosis of acetabular cup loosening using computed tomography - Preliminary experience in 10 patients

Olivecrona, Henrik (författare)
Karolinska Institutet
Olivecrona, Lotta (författare)
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology
Weidenhielm, Lars (författare)
Karolinska Institutet
visa fler...
Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
Kardos, Jocelyn (författare)
New York University, Department of Radiology
Maguire, Gerald Q. Jr. (författare)
KTH,Kommunikationssystem, CoS
Zeleznik, Michael P. (författare)
Saya Systems Inc., Salt Lake City, UT, USA
Aspelin, Peter (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2009-07-08
2008
Engelska.
Ingår i: Acta Orthopaedica. - New York, NY, USA : Informa Healthcare. - 1745-3674 .- 1745-3682. ; 79:3, s. 346-353
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose: Considerable migration of the acetabular cup is required for diagnosis of loosening by conventional radiography. We have developed a new clinically applicable method for assessment of cup loosening using computed tomography (CT). Patients and methods 10 patients scheduled for revision hip replacement due to suspected wear or loosening were scanned twice with CT under torsion loading of the prosthesis. Two independent examiners assessed each patient with respect to motion of the acetabular cup relative to the pelvis using CT volume registration. The CT measurements were compared to findings at revision surgery. Results The method was applicable in 8 of the 10 patients. 1 patient had a severe tremor. In 1 patient, surgery revealed that the hip was ankylotic due to massive ectopic bone formation. This left 8 patients that could be evaluated. 4 cups were loose at surgery, and 3 of these cups could be seen to be mobile by CT. 4 cups that were stable on revision were accurately diagnosed as not being mobile by CT. Movements of less than 1 millimeter between bone and prosthesis could not be distinguished from errors in CT acquisition and volume registration. There was good agreement between the two observers. Interpretation Movement of loose acetabular cups during torsion loading could be detected using CT volume registration. It was sensitive to cup movement in 3 out of 4 cases of loose cups. The method was specific and yielded no false positive results.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

total hip-arthroplasty
semiautomated program
component migration
fusion
ct
radiostereometry
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy