  •  Purpose In two different cases, multifocal intraocular lenses (MFIOLs) were explanted due to visual complications related to the presence of micro-vacuoles in the optic body. These micro-vacuoles cause straylight, which resulted in complaints of hazy and blurry vision. The purpose of this study is to objectively measure and systematically quantify the visual impact of this straylight. The study will thereby give a better understanding of the origin of reported visual complaints when micro-vacuoles are present. Methods The amount of straylight in the two explanted MFIOLs was measured using an in-vitro setup and quantified using the scattering parameter s. To determine the impact of straylight on vision, photographic filters characterized in the same in-vitro setup were used to induce straylight on five subjects. Four different psychophysical visual tests were used: halo size, luminance detection with a glare source, and contrast sensitivity (CS) with and without the presence of glare. For all tests, the impact was modeled as a linear interpolation of the logarithm of the test score against the logarithm of the scattering parameter, log(s). Results The straylight measured by the in-vitro setup was 6 deg2/sr for case 1 and 4 deg2/sr for case 2. Assuming a base straylight level of 1.1 log(s), the induced increase for the two patients was 0.17 log(s) and 0.12 log(s) respectively. The impact for the visual tests per unit of log(s) was the following: for halo size, 0.55 log(degrees)/log(s); for luminance detection 2.72 log(cd/m2)/log(s); for CS without glare, 0.33 log(CS)/log(s); and for CS with glare, 0.58 log(CS)/log(s). The induced straylight for the two explanted MFIOLs therefore corresponds to an increase of halo size of 24% and 16%, a luminance detection threshold increase of 190% and 112%, a contrast sensitivity decrease of 12% and 9% without a glare source, and a contrast sensitivity decrease of 20% and 9% with a glare source. Conclusions In the explanted MFIOLs we could objectively measure straylight. This straylight corresponds psychophysically to increases in halo size, loss of luminance sensitivity and decrease in contrast sensitivity. Among the visual tests, measurement of luminance detection showed the highest sensitivity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy