SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-186029"
 

Sökning: id:"swepub:oai:DiVA.org:kth-186029" > Oxidation-reduction...

Oxidation-reduction potential (ORP) as a control parameter in a single-stage partial nitritation/anammox process treating reject water

Yang, Jingjing (författare)
KTH,Mark- och vattenteknik,Swedish Environmental Research Institute (IVL), Sweden
Trela, Jozef (författare)
KTH,Mark- och vattenteknik,Swedish Environmental Research Institute (IVL), Sweden,Land and water resources engineering
Plaza, Elzbieta (författare)
KTH,Mark- och vattenteknik
visa fler...
Wahlberg, Olle (författare)
KTH,Kemi
Levlin, Erik (författare)
KTH,Hållbar utveckling, miljövetenskap och teknik
visa färre...
 (creator_code:org_t)
2015-12-29
2016
Engelska.
Ingår i: Journal of chemical technology and biotechnology (1986). - : John Wiley & Sons. - 0268-2575 .- 1097-4660. ; 91:10, s. 2582-2589
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BBACKGROUND: Redox potential value (or pE) can be used as a monitoring parameter for deammonification processes treating reject water. In this study its use as a control parameter was investigated. Experiments were carried out with a one-stage partial nitritation/anammox process in a 200 L moving bed biofilm reactor (MBBR) with 40% filled Kaldnes biofilm carriers. RESULTS: Tests on different combinations of nitrogen loads (1.8-3.3 gN m-2 d-1) and pE values (-1, 0, 1) revealed that process performance was stable and nitrogen removal efficiency >80% was achieved at all tested pE values except pE=-1. A value close to pE=0 was the most suitable in terms of process performance at 25°C at all tested pE values. With a fixed redox potential value (pE=0) used in the system, the air supply adjusted automatically under different nitrogen loads and maintained a high nitrogen removal efficiency. Theoretical calculations showed that pE>0.15 (at pH=7) provides conditions for nitrite conversion into nitrate at 25°C. CONCLUSION: Redox control turned out to be a suitable control parameter for operation of a partial nitritation/anammox process. A redox value of 0 was a suitable value under different nitrogen loads in this pilot-scale study. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)

Nyckelord

single-stage partial nitritation/anammox process
oxidation-reduction potential (ORP)
process control strategy
reject water treatment
Byggvetenskap
Civil and Architectural Engineering

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy