SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-186895"
 

Sökning: id:"swepub:oai:DiVA.org:kth-186895" > Multiplex PCB-based...

Multiplex PCB-based electrochemical detection of cancer biomarkers using MLPA-barcode approach

Sánchez, J. L. A. (författare)
Henry, O. Y. F. (författare)
Joda, H. (författare)
visa fler...
Solnestam, Beata Werne (författare)
KTH,Genteknologi,Science for Life Laboratory, SciLifeLab
Kvastad, Linda (författare)
KTH,Genteknologi,Science for Life Laboratory, SciLifeLab
Johansson, Elin (författare)
KTH,Genteknologi,Science for Life Laboratory, SciLifeLab
Akan, Pelin (författare)
KTH,Genteknologi,Science for Life Laboratory, SciLifeLab
Lundeberg, Joakim (författare)
KTH,Genteknologi,Science for Life Laboratory, SciLifeLab
Lladach, N. (författare)
Ramakrishnan, D. (författare)
Riley, I. (författare)
O'Sullivan, C. K. (författare)
visa färre...
 (creator_code:org_t)
Elsevier, 2016
2016
Engelska.
Ingår i: Biosensors & bioelectronics. - : Elsevier. - 0956-5663 .- 1873-4235. ; 82, s. 224-232
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Asymmetric multiplex ligation-dependent probe amplification (MLPA) was developed for the amplification of seven breast cancer related mRNA markers and the MLPA products were electrochemically detected via hybridization. Seven breast cancer genetic markers were amplified by means of the MLPA reaction, which allows for multiplex amplification of multiple targets with a single primer pair. Novel synthetic MLPA probes were designed to include a unique barcode sequence in each amplified gene. Capture probes complementary to each of the barcode sequences were immobilized on each electrode of a low-cost electrode microarray manufactured on standard printed circuit board (PCB) substrates. The functionalised electrodes were exposed to the single-stranded MLPA products and following hybridization, a horseradish peroxidase (HRP)-labelled DNA secondary probe complementary to the amplified strand completed the genocomplex, which was electrochemically detected following substrate addition. The electrode arrays fabricated using PCB technology exhibited an excellent electrochemical performance, equivalent to planar photolithographically-fabricated gold electrodes, but at a vastly reduced cost (>50 times lower per array). The optimised system was demonstrated to be highly specific with negligible cross-reactivity allowing the simultaneous detection of the seven mRNA markers, with limits of detections as low as 25 pM. This approach provides a novel strategy for the genetic profiling of tumour cells via integrated "amplification-to-detection".

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)

Nyckelord

Barcodes
Breast cancer markers
Electrochemical detection
Multiplex ligation-dependent probe amplification system (MLPA)
PCB genosensor arrays
Amplification
Bar codes
Biomarkers
Chemical detection
Diseases
Electrodes
Gain control
Multiplexing
Nucleic acids
Printed circuit boards
Printed circuits
Probes
Substrates
Breast Cancer
Electrochemical performance
Genosensors
Horseradish peroxidase
Printed circuit boards (PCB)
Probe amplification
Simultaneous detection
Electrochemical electrodes

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy