Predicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis

Klintström, Eva (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Klintström, Benjamin (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Moreno, Rodrigo (författare)
KTH,Skolan för teknik och hälsa (STH),KTH Royal Institute of Technology, School of Technology and Health, Huddinge, Stockholm, Sweden
visa fler...
Brismar, Torkel B. (författare)
Karolinska Institutet,Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden; Department of Radiology, Karolinska University Hospital, Huddinge, Stockholm, Sweden
Pahr, Dieter H. (författare)
Institute of Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria
Smedby, Örjan, Professor, 1956- (författare)
Linköpings universitet,KTH,Skolan för teknik och hälsa (STH),Avdelningen för radiologiska vetenskaper,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinska fakulteten,Region Östergötland, Röntgenkliniken i Linköping
visa färre...
 (creator_code:org_t)
2016-08-11
2016
Engelska.
Ingår i: PLOS ONE. - : PLOS one. - 1932-6203. ; 11:8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Stiffness and shear moduli of human trabecular bone may be analyzed in vivo by finite element (FE) analysis from image data obtained by clinical imaging equipment such as high resolution peripheral quantitative computed tomography (HR-pQCT). In clinical practice today, this is done in the peripheral skeleton like the wrist and heel. In this cadaveric bone study, fourteen bone specimens from the wrist were imaged by two dental cone beam computed tomography (CBCT) devices and one HR-pQCT device as well as by dual energy X-ray absorptiometry (DXA). Histomorphometric measurements from micro-CT data were used as gold standard. The image processing was done with an in-house developed code based on the automated region growing (ARG) algorithm. Evaluation of how well stiffness (Young's modulus E3) and minimum shear modulus from the 12, 13, or 23 could be predicted from the CBCT and HR-pQCT imaging data was studied and compared to FE analysis from the micro-CT imaging data. Strong correlations were found between the clinical machines and micro-CT regarding trabecular bone structure parameters, such as bone volume over total volume, trabecular thickness, trabecular number and trabecular nodes (varying from 0.79 to 0.96). The two CBCT devices as well as the HR-pQCT showed the ability to predict stiffness and shear, with adjusted R-2-values between 0.78 and 0.92, based on data derived through our in-house developed code based on the ARG algorithm. These findings indicate that clinically used CBCT may be a feasible method for clinical studies of bone structure and mechanical properties in future osteoporosis research.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy