SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-19399"
 

Sökning: id:"swepub:oai:DiVA.org:kth-19399" > Stability of Poly(3...

Stability of Poly(3,4-ethylene dioxythiophene) Materials Intended for Implants

Thaning, Elin M. (författare)
KTH,Neuronik,Royal Institute of Technology
Asplund, Maria (författare)
KTH,Neuronik,Royal Institute of Technology
Nyberg, Tobias (författare)
KTH,Neuronik,Royal Institute of Technology
visa fler...
Inganäs, Olle (författare)
Linköpings universitet,Biomolekylär och Organisk Elektronik,Tekniska högskolan
von Holst, Hans (författare)
KTH,Neuronik,Royal Institute of Technology
visa färre...
 (creator_code:org_t)
2010-02-02
2010
Engelska.
Ingår i: Journal of Biomedical Materials Research - Part B Applied Biomaterials. - : Wiley. - 1552-4973 .- 1552-4981. ; 93B:2, s. 407-415
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study presents experiments designed to study the stability of the conducting polymer poly(3,4-ethylene dioxythiophene) (PEDOT), under simulated physiological conditions using phosphate-buffered saline (PBS) and hydrogen peroxide (H2O2) (0 01M) at 37 degrees C over a 5- to 6-week period Voltage pulsing in PBS was used as an additional test environment The influence of switching the counter ion used in electropolymerization from polystyrene sulphonate (PSS) to heparin was investigated Absorbance spectroscopy and cyclic voltammetry were used to evaluate the material properties Most of the samples in H2O2 lost both electroactivity and optical absorbance within the study period, but PEDOT.PSS was found slightly more stable than PEDOT heparin. Polymers were relatively stable in PBS throughout the study period, with around 80% of electroactivity remaining after 5 weeks, disregarding delamination, which was a significant problem especially for polymer on indium tin oxide substrates Voltage pulsing in PBS did not increase degradation. The counter ion influenced the time course of degradation in Oxidizing agents.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

PEDOT
stability
degradation
conjugated polymers
neural prosthesis
Medical engineering
Medicinsk teknik
TECHNOLOGY

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy