SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-20379"
 

Sökning: id:"swepub:oai:DiVA.org:kth-20379" > Deterioration in pe...

Deterioration in peak systolic velocity is closely related to ischaemia during angioplasty : a vectorcardiographic and tissue Doppler imaging study

Jensen, J. (författare)
Karolinska Institutet
Brodin, Lars-Åke (författare)
Karolinska Institutet
Lind, B. (författare)
visa fler...
Eriksson, S. V. (författare)
Karolinska Institutet
Jensen-Urstad, M. (författare)
Sylven, C. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2000-12-20
2001
Engelska.
Ingår i: Clinical Science. - : Portland Press Ltd.. - 0143-5221 .- 1470-8736. ; 100:2, s. 137-143
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We tested the hypothesis that the extent of signs of ischaemia detected by vectorcardiography (VCG) during elective coronary angioplasty (percutaneous transluminal coronary angioplasty: PTCA) is related to systolic and diastolic myocardial velocities, as determined by tissue Doppler echocardiography. A total of 15 patients undergoing PTCA (12 men/three women; age 61 +/- 9 years), without prior myocardial infarction and with an election fraction of > 50%, were included. The balloon inflation was repeated three times, with minimum intervals of 2 min between inflations. Tissue Doppler echocardiography was performed. in an apical two- or four-chamber view, before and at the end of each inflation. Peak systolic velocity, time-to-peak systolic velocity (TTP), peak early (E-m) and late (A(m)) diastolic velocities, the E-m/A(m) ratio and jsovolumic relaxation time were measured in the basal segments of the left ventricle. VCG recordings were carried out during the whole procedure. ST vector magnitude (ST-VM) and ST change vector magnitude (STC-VM) were monitored. The total duration and area of each VCG change during inflation were calculated for each patient. Isovolumic relaxation time, peak E-m and A(m) values and the E-m/A(m) ratio did not change significantly during inflation. Peak systolic velocity decreased (6.7+/-2.0 to 5.3 +/- 1.9 cm/s; P < 0.001) and TTP increased (157 +/- 60 to 192 +/- 60 ms; P<0.01) during inflation. Both STC-VM rime (r = -0.68, P<0.01) and STC-VM area (r = -0.68, P < 0.01) were related to peak systolic velocity during inflation. STC-VM time was also related (r = 0.55, P < 0.05) to the difference in peak systolic velocity during compared with before inflation. ST-VM was less closely related to peak systolic velocity. Thus the duration and degree of ischaemia, as measured by VCG, are related to peak systolic velocity in the basal segments of the left ventricle.

Nyckelord

angioplasty
myocardial ischaemia
tissue Doppler echocardiography
vectorcardiography
transluminal coronary angioplasty
online computerized vectorcardiography
myocardial-ischemia
artery
occlusion
echocardiography
reperfusion
risk

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy