  • The parameters for load and resistance factor design (LRFD) of driven piles using dynamic methods are presented based on a database of 218 pile cases in Florida. Eight dynamic methods were studied: ENR, modified ENR, FDOT, and Gates driving formulas, Case Analysis with Wave Analysis Program (CAPWAP), Case Method for Pile Driving Analyzer (PDA), Paikowsky's energy method, and Sakai's energy method. It was demonstrated that the modern methods based on wave mechanics, such as CAPWAP, PDA, and Paikowsky's energy methods, are roughly twice as cost effective to reach the target reliability indices of 2.0 to 2.5 (failure probability = 0.62 to 2.5%) as the ENR and modified ENR driving formulas. The Gates formula, when used separately on piles with Davisson capacities smaller or larger than 1779 kN, has an accuracy comparable to the modem methods. The utilizable measured Davisson capacity, defined as phi/lambda (ratio of resistance/mean capacity) obtained from testing at beginning of redrive (BOR), is only slightly larger than the end of drive (EOD) values. Furthermore, past practice with driving formulas reveals the existence of a large redundancy in pile groups against failure. The latter suggests the use of a lower relatively reliability target index, B-T = 2.0 (p(f) = 2.5%) for single pile design. Also, the utilizable measured Davisson capacity, phi/lambda, for all the dynamic methods studied, is quite similar to published values (Lai et al. 1995; Sid; 1985) for static estimates from in situ tests.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Nyckelord

pile foundation
pile driving
reliability
load and resistance factor design

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
McVay, M. C.
Birgisson, Björn
Zhang, L. M.
Perez, A.
Putcha, S.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
Artiklar i publikationen
ASTM geotechnica ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy