Sökning: id:"swepub:oai:DiVA.org:kth-234314" >
An add-on filter te...
An add-on filter technique to improve micropollutant removal and water quality in on-site sewage treatment facilities
-
- Zhang, Wen (författare)
- KTH,Vatten- och miljöteknik
-
- Renman, Gunno (preses)
- KTH,Vatten- och miljöteknik
-
- Kärrman, Erik, PhD (preses)
- Urban Water management at RISE Research Institues of Sweden
-
visa fler...
-
- Arias, Carlos Alberto (opponent)
- Aarhus University, Aarhus, Denmark
-
visa färre...
-
(creator_code:org_t)
- ISBN 9789177299363
- Stockholm : KTH Royal Institute of Technology, 2018
- Engelska 54 s.
- Relaterad länk:
-
https://kth.diva-por... (primary) (Raw object)
-
visa fler...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Onsite sewage treatment facilities (OSSFs) in Sweden currently release significant amounts of nitrogen (N) and phosphorus (P) into groundwater or/and receiving water bodies. Micropollutants (MPs) have been found in both surface water and groundwater, indicating insufficient removal of MPs by OSSFs. Two laboratory-scale column experiments, followed by a field experiment, were performed to study removal of a set of organic MPs by organic and inorganic sorbents. The set covered different product categories, e.g. an artificial sweetener, organophosphates, parabens, personal care products, perfluoroalkyl substances (PFASs), pesticides, pharmaceuticals, a plasticiser, a polymer impurity, stimulants and surfactants. An experiment using five organic and five inorganic sorbents showed that coal-based organic sorbents performed better than natural fibre and inorganic sorbents in removal of MPs, with 20% higher removal efficiency on average. Five sorbents were selected for a long-term column experiment examining 31 MPs. Physical properties and chemical structure of the sorbents, namely pore structure and surface functional groups, were found to be correlated to their capacity for removal of MPs. Molecular weight, solvent-accessible area, octanol-water partition coefficient and distribution-coefficient of PFASs were found to be strongly positively correlated with their removal by some sorbents. Organic sorbents with good performance in removal of MPs and a conventional sand bed showed limited ability to remove P, while calcium-rich sorbents increased P removal greatly. Two sorbents, granulated activated carbon (GAC) and xyloid lignite (Xylit), were tested for 24 weeks in an add-on filter for effluent from a soil treatment system and found to significantly improve removal of MPs. A replaceable add-on unit for removal of MPs from OSSF effluent is recommended and should contain an organic sorbent such as GAC or Xylit.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Water Engineering (hsv//eng)
Nyckelord
- Micropollutant
- on-site sewage facilities
- physicochemical properties
- pore structure
- sorbents
- surface functional group
- Mark- och vattenteknik
- Land and Water Resources Engineering
Publikations- och innehållstyp
- vet (ämneskategori)
- dok (ämneskategori)
Hitta via bibliotek
Till lärosätets databas