SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-239084"
 

Sökning: id:"swepub:oai:DiVA.org:kth-239084" > In vivo measurement...

In vivo measurement of the effective atomic number of breast skin using spectral mammography

Berggren, Karl (författare)
KTH,Medicinsk bildfysik,Royal Inst Technol KTH, Dept Phys, Stockholm, Sweden.;Philips Mammog Solut, Kista, Sweden.
Eriksson, Mikael (författare)
Karolinska Institutet
Hall, Per (författare)
Karolinska Institutet
visa fler...
Walliss, Matthew G. (författare)
Addenbrookes Hosp, Cambridge Breast Unit, Cambridge, England.;Addenbrookes Hosp, NIHR Cambridge Biomed Res Ctr, Cambridge, England.
Fredenberg, Erik (författare)
Philips Res, Kista, Sweden.
visa färre...
 (creator_code:org_t)
2018-10-30
2018
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics Publishing (IOPP). - 0031-9155 .- 1361-6560. ; 63:21
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • X-ray characteristics of body tissues are of crucial importance for developing and optimizing x-ray imaging techniques, in particular for dosimetry and spectral imaging applications. For breast imaging, the most important tissues are fibro-glandular, adipose and skin tissue. Some work has and is being done to better characterize these tissue types, in particular fibro-glandular and adipose tissue. In the case of breast skin, several recent studies have been published on the average skin thickness, but with regards to x-ray attenuation, the only published data, to the knowledge of the authors, is the elemental composition analysis of Hammerstein et al (1979 Radiology 130 485-91). This work presents an overview of breast skin thickness studies and a measurement of the effective atomic number (Z(eff)) of breast skin using spectral mammography. Z(eff), which together with the density forms the attenuation, is used to validate the work by Hammerstein et al, and the dependence of clinical parameters on Z(eff) is explored. Measurements were conducted on the skin edge of spectral mammograms using clinical data from a screening population (n = 709). The weighted average of breast skin thickness reported in studies between 1997 and 2013 was found to be 1.56 +/- 0.28 mm. Mean Z(eff) was found to be 7.365 (95% CI: 7.364,7.366) for normal breast skin and 7.441 (95% CI: 7.440,7.442) for the nipple and areola. Z(eff) of normal breast skin is in agreement with Hammerstein et al, despite the different methods and larger sample size used. A small but significant increase in Z(eff) was found with age, but the increase is too small to be relevant for most applications. We conclude that normal breast skin is well described by a 1.56 mm skin layer and the elemental composition presented by Hammerstein et al (1979 Radiology 130 485-91) and recommend using these characteristics when modelling breast skin.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

effective atomic number
skin
spectral imaging
mammography
x-ray attenuation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub