WARD : Wear aware RAID design within SSDs

Wang, S. (författare)
Wu, F. (författare)
Lu, Zhonghai (författare)
KTH,Elektronik och inbyggda system
visa fler...
Zhou, J. (författare)
Xie, C. (författare)
visa färre...
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers Inc. 2018
2018
Engelska.
Ingår i: IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems. - : Institute of Electrical and Electronics Engineers Inc.. - 0278-0070 .- 1937-4151. ; 37:11, s. 2918-2928
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Redundant arrays of independent disk (RAID) is an efficient approach to relieve reliability sacrifice caused by aggressive scale-out of solid state drives (SSDs). Unfortunately, RAID is unfriendly to SSDs due to redundant parity write and data rebuilding. This paper proposes a wear aware RAID design for SSDs, called WARD, which: 1) adaptively organizes RAID stripes according to real-time interblock unbalanced wear for relieving high performance and storage overhead caused by parity data and 2) migrates blocks about to break in advance and leaves these blocks unused to reduce data rebuilding overhead. An efficient block wear detection scheme is employed to detect block wear during the whole lifetime of SSDs. Beginning with a large stripe width RAID instead of the redundant worst-case RAID, WARD reorganizes RAID stripes once wear blocks with high bit error rates come out. WARD divides the original stripe into several short width RAID stripes according to the number of wear blocks and separates all wear blocks into different stripes. This not only reduces parity redundancy but also provides high reliability to avoid more than RAID recoverable error-prone chunks remaining in one stripe. For high wear blocks tending to wear-out, data in them are migrated in advance and then the blocks are left unused, which efficiently avoids performance shock caused by data rebuilding. A reliability model considering interblock unbalanced wear is proposed and reveals that WARD provides a high and stable reliability and greatly prolongs the lifetime of SSDs. Comprehensive experiments based on an SSDsim derivative simulator are carried out and experiment results show that WARD considerably improves system performance compared to the worst-case RAID.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Performance
redundant arrays of independent disk (RAID) within solid state drives (SSDs)
reliability
wear aware
Digital storage
Redundancy
High bit error rates
High reliability
Reliability model
Solid state drives
Stable reliability
Storage overhead
Wear detection
Wear of materials

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wang, S.
Wu, F.
Lu, Zhonghai
Zhou, J.
Xie, C.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy