SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-297088"
 

Sökning: id:"swepub:oai:DiVA.org:kth-297088" > Validity of a small...

Validity of a small low-cost triaxial accelerometer with integrated logger for uncomplicated measurements of postures and movements of head, upper back and upper arms

Dahlqvist, Camilla (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Arbetsrelaterade besvär i rörelseorganen,Forskargrupper vid Lunds universitet,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine,Work-related musculoskeletal disorders,Lund University Research Groups,Regional Laboratories Region Skåne
Hansson, Gert-Åke (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Arbetsrelaterade besvär i rörelseorganen,Forskargrupper vid Lunds universitet,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine,Work-related musculoskeletal disorders,Lund University Research Groups,Regional Laboratories Region Skåne
Forsman, Mikael, Professor (författare)
Karolinska Institutet,Karolinska Institute
 (creator_code:org_t)
Elsevier, 2016
2016
Engelska.
Ingår i: Applied Ergonomics. - : Elsevier. - 0003-6870 .- 1872-9126. ; 55, s. 108-116
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Repetitive work and work in constrained postures are risk factors for developing musculoskeletal disorders. Low-cost, user-friendly technical methods to quantify these risks are needed. The aims were to validate inclination angles and velocities of one model of the new generation of accelerometers with integrated data loggers against a previously validated one, and to compare meaurements when using a plain reference posture with that of a standardized one. All mean (n = 12 subjects) angular RMS-differences in 4 work tasks and 4 body parts were <2.5° and all mean median angular velocity differences <5.0 °/s. The mean correlation between the inclination signal-pairs was 0.996. This model of the new generation of triaxial accelerometers proved to be comparable to the validated accelerometer using a data logger. This makes it well-suited, for both researchers and practitioners, to measure postures and movements during work. Further work is needed for validation of the plain reference posture for upper arms.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

Quantitative exposure-response relationships
Technical measurements
Work-related musculoskeletal disorders

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy