SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-309668"
 

Sökning: id:"swepub:oai:DiVA.org:kth-309668" > Functionalized grap...

Functionalized graphene oxide tablets for sample preparation of drugs in biological fluids : Extraction of ritonavir, a HIV protease inhibitor, from human saliva and plasma using LC–MS/MS

Zohdijamil, Zeynab (författare)
Karolinska institutet
Hashemi, M. (författare)
Abdel-Rehim, A. (författare)
visa fler...
Laxman, Karthik (författare)
KTH,Material- och nanofysik
Uheida, Abdusalam (författare)
KTH,Material- och nanofysik
Dutta, Joydeep (författare)
KTH,Material- och nanofysik
Abdel-Rehim, Mohamed (författare)
KTH,Material- och nanofysik
visa färre...
 (creator_code:org_t)
2021-06
2021
Engelska.
Ingår i: BMC Biomedical chromotography. - : Wiley. - 0269-3879 .- 1099-0801. ; 35:12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this work, graphene oxide–based tablets (GO-Tabs) were prepared by applying a thin layer of functionalized GO on a polyethylene substrate. The GO was functionalized with amine groups (–NH2) by poly(ethylene glycol)bis(3-aminopropyl) terminated (GO-NH2-PEG-NH2). The functionalized GO-Tabs were used for the extraction of ritonavir (RTV) in human saliva samples. RTV in plasma and saliva samples was analyzed using LC–MS/MS. Gradient LC system with MS/MS in the positive-ion mode [electrospray ionization (ESI+)] was used. The transitions m/z 721 → 269.0 and m/z 614 → 421 were used for RTV and the internal standard indinavir, respectively. This study determined the human immunodeficiency virus protease inhibitor RTV in human saliva samples using functionalized GO-Tab and LC–MS/MS, and the method was validated. The standard calibration curve for plasma and saliva samples was constructed from 5.0 to 2000 nmol L−1. The limit of detection was 0.1 nmol L−1, and the limit of quantification was 5.0 nmol L−1 in both plasma and saliva matrices. The intra- and inter-assay precision values were found to be between 1.5 and 5.8%, and the accuracy values ranged from 88.0 to 108% utilizing saliva and plasma samples. The extraction recovery was more than 80%, and the presented functionalized GO-Tabs could be reused for more than 10 extractions without deterioration in recovery.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

graphene oxide tablets
LC–MS/MS
plasma
ritonavir
saliva
amine
graphene oxide
macrogol derivative
nanocomposite
poly(ethylene glycol)bis (3 aminopropyl)
polyethylene
unclassified drug
graphite
Human immunodeficiency virus proteinase inhibitor
nanomaterial
blood sampling
Conference Paper
drug determination
drug synthesis
human
hydrogen bond
limit of detection
limit of quantitation
liquid chromatography-mass spectrometry
positive ion electrospray
saliva analysis
tablet
chemistry
liquid chromatography
procedures
reproducibility
statistical model
tablet manufacture
tandem mass spectrometry
Chromatography
Liquid
HIV Protease Inhibitors
Humans
Linear Models
Nanostructures
Reproducibility of Results
Tablets

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy