Imaging Sample Acidification Triggered by Electrochemically Activated Polyaniline

Steininger, Fabian (författare)
Aarhus University Centre for Water Technology, Department of Biology, Section for Microbiology, Aarhus University, 8000 Aarhus, Denmark
Wiorek, Alexander (författare)
KTH,Tillämpad fysikalisk kemi
Crespo, Gaston A., 1980- (författare)
KTH,Tillämpad fysikalisk kemi
visa fler...
Koren, Klaus (författare)
Aarhus University Centre for Water Technology, Department of Biology, Section for Microbiology, Aarhus University, 8000 Aarhus, Denmark
Cuartero, Maria, PhD, 1984- (författare)
KTH,Tillämpad fysikalisk kemi
visa färre...
 (creator_code:org_t)
2022-09-27
2022
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 94:40, s. 13647-13651
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this letter, we demonstrate 2D acidification of samples at environmental and physiological pH with an electrochemically activated polyaniline (PANI) mesh. A novel sensor–actuator concept is conceived for such a purpose. The sample is sandwiched between the PANI (actuator) and a planar pH optode (sensor) placed at a very close distance (∼0.50 mm). Upon application of a mild potential to the mesh, in contrast to previously reported acidification approaches, PANI releases a significant number of protons, causing an acid–base titration in the sample. This process is monitored in time and space by the pH optode, providing chemical imaging of the pH decrease along the dynamic titration via photographic acquisition. Acidification of samples at varying buffer capacity has been investigated: the higher the buffer capacity, the more time (and therefore proton charge) was needed to reach a pH of 4.5 or even lower. Also, the ability to map spatial differences in buffer capacity within a sample during the acid–base titration was unprecedentedly proven. The sensor–actuator concept could be used for monitoring certain analytes in samples that specifically require acidification pretreatment. Particularly, in combination with different optodes, dynamic mapping of concentration gradients will be accessible in complex environmental samples ranging from roots and sediments to bacterial aggregates.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy