SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-345945"
 

Sökning: id:"swepub:oai:DiVA.org:kth-345945" > Impact of Synchrono...

Impact of Synchronous Condensers' Ratings on Mitigating Subsynchronous Oscillations in Wind Farms

Dimitropoulos, Dimitrios (författare)
Aalborg Univ, AAU Energy, DK-9220 Aalborg, Denmark.
Bakhshizadeh, Mohammad Kazem (författare)
Orsted Wind Power AS, DK-2820 Gentofte, Denmark.
Kocewiak, Lukasz (författare)
Orsted Wind Power AS, DK-2820 Gentofte, Denmark.
visa fler...
Wang, Xiongfei (författare)
KTH,Elkraftteknik,Aalborg Univ, AAU Energy, DK-9220 Aalborg, Denmark
Blaabjerg, Frede (författare)
Aalborg Univ, AAU Energy, DK-9220 Aalborg, Denmark.
visa färre...
Aalborg Univ, AAU Energy, DK-9220 Aalborg, Denmark Orsted Wind Power AS, DK-2820 Gentofte, Denmark. (creator_code:org_t)
MDPI AG, 2024
2024
Engelska.
Ingår i: Energies. - : MDPI AG. - 1996-1073. ; 17:7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Subsynchronous oscillations have occurred in wind farms due to the high penetration of converter-based technology in power systems and may potentially lead to grid instability. As an effective solution, synchronous condensers, with their ability to control voltage and inject reactive power in the power system, are increasingly being adopted, as they can lead to the mitigation of such oscillations in weak grid conditions. However, the impact of synchronous condensers' power ratings on system stability is a topic that requires further investigation. In fact, an improper selection of a synchronous condenser's rating will not extinguish existing subsynchronous oscillations and may even cause the emergence of new oscillatory phenomena. This paper presents a novel examination of the impact that the synchronous condenser's power rating has on the small-signal stability of a wind farm with existing subsynchronous oscillations while being connected to a weak grid. The wind farm's model is developed using state-space modeling, centering on grid interconnection and incorporating the state-space submodel of a synchronous condenser to show its impact on subsynchronous oscillation mitigation. The stability analysis determines the optimal synchronous condenser's power ratings for suppressing these oscillations in the wind farm model. The findings are corroborated through time domain simulations and fast-Fourier transformation (FFT) analysis, which further validate the stability effects of a synchronous condenser's rating.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

subsynchronous oscillations
mitigating measures
synchronous condenser
stability analysis
state-space model
grid-following converter control
time domain simulations

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Energies (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng