SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-50158"
 

Sökning: id:"swepub:oai:DiVA.org:kth-50158" > Comparison of three...

Comparison of three methods for registration of abdominal/pelvic volume data sets from functional-anatomic scans

Mahmoud, Faaiza (författare)
New York University
Ton, Anthony (författare)
New York University
Crafoord, Joakim (författare)
Department of Radiology, Karolinska Hospital
visa fler...
Kramer, Elissa L. (författare)
New York University
Maguire Jr., Gerald Q. (författare)
KTH,Teleinformatik
Noz, Marilyn E. (författare)
New York University
Zeleznik, Michael P. (författare)
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2000
2000
Engelska.
Ingår i: SPIE - The International Society for Optical Engineering. - : SPIE - International Society for Optical Engineering. ; , s. 1378-1386
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this work was to evaluate three volumetric registration methods in terms of technique, user-friendliness and time requirements. CT and SPECT data from 11 patients were interactively registered using: a 3D method involving only affine transformation; a mixed 3D - 2D non-affine (warping) method; and a 3D non-affine (warping) method. In the first method representative isosurfaces are generated from the anatomical images. Registration proceeds through translation, rotation, and scaling in all three space variables. Resulting isosurfaces are fused and quantitative measurements are possible. In the second method, the 3D volumes are rendered co-planar by performing an oblique projection. Corresponding landmark pairs are chosen on matching axial slice sets. A polynomial warp is then applied. This method has undergone extensive validation and was used to evaluate the results. The third method employs visualization tools. The data model allows images to be localized within two separate volumes. Landmarks are chosen on separate slices. Polynomial warping coefficients are generated and data points from one volume are moved to the corresponding new positions. The two landmark methods were the least time consuming (10 to 30 minutes from start to finish), but did demand a good knowledge of anatomy. The affine method was tedious and required a fair understanding of 3D geometry.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy