Assessing wear of the acetabular cup using computed tomography : an ex vivo study

Olivecrona, Lotta (författare)
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology
Jedenmalm, Anneli (författare)
KTH,Materialvetenskap
Aspelin, Peter (författare)
Karolinska Institutet
visa fler...
Weidenhielm, Lars (författare)
Karolinska Institutet
Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
Maguire Jr., Gerald Q. (författare)
KTH,Kommunikationssystem, CoS,Computer Communications
Zeleznik, Michael P. (författare)
RAHD Oncology Products, St. Louis. Mo
Olivecrona, Henrik (författare)
Department of Hand Surgery, Södersjukhuset, Stockholm
visa färre...
 (creator_code:org_t)
2016-08-30
2005
Engelska.
Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 46:8, s. 852-857
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To validate a clinically useful method for measuring acetabular cup wear using computed tomography (CT). Material and Methods: Eight uncemented acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral component head into the cup and the thickness of the remaining polyethylene liner were measured in the CT volumes using dedicated software. Two independent examiners twice assessed each volume. The CT measurements were compared to direct measurements using a coordinate measuring device and micrometer measurements. Results: Accuracy of wear measurements expressed as penetration depth was +/- 0.6 and +/- 1.0 mm for the two examiners, respectively, with no significant differences between examiners, trials, and CT scans. Accuracy of measurements of remaining polyethylene was +/- 1.3 and +/- 1.0 mm, respectively, for the two examiners. Systematic differences between examiners were found, but no significant differences between trials and CT scans. These differences were due to different interpretations of metal artifacts in the volumes. Conclusion: The proposed CT method for evaluating wear as head penetration depth allows for reliable wear detection at a clinically relevant level. Measurements of remaining polyethylene on CT volumes are not as reliable as wear measurements owing to metal artifacts.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Adults
Computer applications-3D
Hip
CT
Hip
skeletal
Hip
spiral
Technical aspects
Medical engineering
Medicinsk teknik
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy