SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-7155"
 

Sökning: id:"swepub:oai:DiVA.org:kth-7155" > Effect of optical c...

Effect of optical correction and remaining aberrations on peripheral resolution acuity in the human eye

Lundström, Linda (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Manzanera, Silvestre (författare)
Laboratorio de Optica, Universidad de Murcia
Prieto, Pedro (författare)
Laboratorio de Optica, Universidad de Murcia
visa fler...
Ayala, Diego (författare)
Laboratorio de Optica, Universidad de Murcia
Gorceix, Nicolas (författare)
Laboratorio de Optica, Universidad de Murcia
Gustafsson, Jörgen (författare)
School of Optometry, Kalmar University
Unsbo, Peter (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Artal, Pablo (författare)
Laboratorio de Optica, Universidad de Murcia
visa färre...
 (creator_code:org_t)
2007
2007
Engelska.
Ingår i: Optics Express. - 1094-4087. ; 15:20, s. 12654-12661
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Retinal sampling poses a fundamental limit to resolution acuity in the periphery. However, reduced image quality from optical aberrations may also influence peripheral resolution. In this study, we investigate the impact of different degrees of optical correction on acuity in the periphery. We used an adaptive optics system to measure and modify the off-axis aberrations of the right eye of six normal subjects at 20 degrees eccentricity. The system consists of a Hartmann-Shack sensor, a deformable mirror, and a channel for visual testing. Four different optical corrections were tested, ranging from foveal sphero-cylindrical correction to full correction of eccentric low- and high-order monochromatic aberrations. High-contrast visual acuity was measured in green light using a forced choice procedure with Landolt C's, viewed via the deformable mirror through a 4.8-mm artificial pupil. The Zernike terms mainly induced by eccentricity were defocus and with- and against-the-rule astigmatism and each correction condition was successfully implemented. On average, resolution decimal visual acuity improved from 0.057 to 0.061 as the total root-mean-square wavefront error changed from 1.01 mu m to 0.05 mu m. However, this small tendency of improvement in visual acuity with correction was not significant. The results suggest that for our experimental conditions and subjects, the resolution acuity in the periphery cannot be improved with optical correction.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Aberrations; Mean square error; Optical resolving power; Optical sensors; Wavefronts; Optical correction; Resolution acuity; Resolution decimal visual acuity; Root-mean-square wavefront error; Optical variables control
Optics
Optik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy