SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-98180"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-98180" > X-ray phase contras...

X-ray phase contrast angiography using CO 2 as contrast agent

Lundström, Ulf (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Larsson, Daniel H. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Takman, Per (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa fler...
Scott, L. (författare)
Burvall, Anna (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Hertz, Hans M. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2012
2012
Engelska.
Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE - International Society for Optical Engineering. - 9780819489623 ; , s. 83135J-
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • We investigate the possibility of using x-ray in-line phase-contrast imaging with gaseous carbon dioxide as contrast agent to visualize small blood vessels. These are difficult to image at reasonable radiation doses using the absorption of conventional iodinated contrast agents. In-line phase contrast is a method for retrieving information on the electron density of the sample as well as the absorption, by moving the detector away from the sample to let phase variations in the transmitted x-rays develop into intensity variations at the detector. Blood vessels are normally difficult to observe in phase contrast even with iodinated contrast agents as the density difference compared to most tissues is small. Carbon dioxide is a clinically accepted x-ray contrast agent. The gas is injected into the blood stream of patients to temporarily displace the blood in a region and thereby reduce the x-ray absorption in the blood vessels. This gives a large density difference which is ideal for phase-contrast imaging. We demonstrate the possibilities of the method by imaging the arterial system of a rat kidney injected with carbon dioxide. Vessels down to 23 ÎŒm in diameter are shown. The method shows potential for live small-animal imaging.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

angiography
CO 2
phase contrast
x-ray
Arterial systems
Blood streams
Contrast agent
Density difference
In-line
In-line phase contrast
In-phase
Intensity variations
Iodinated contrast agents
Phase contrasts
Phase variation
Phase-contrast imaging
Rat kidneys
Small animal imaging
X ray phase contrast
Blood vessels
Medical imaging
Tissue
X rays
Carbon dioxide

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy