SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-101107"
 

Sökning: id:"swepub:oai:DiVA.org:liu-101107" > Quantification of S...

Quantification of Stenotic Flow Using Spiral 3D Phase-Contrast MRI

Petersson, Sven (författare)
Linköpings universitet,Institutionen för medicin och hälsa,Hälsouniversitetet,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Dyverfeldt, Petter (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Sigfridsson, Andreas (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Fysiologiska kliniken US
visa fler...
Lantz, Jonas (författare)
Linköpings universitet,Medie- och Informationsteknik,Tekniska högskolan
Carlhäll, Carl-Johan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Fysiologiska kliniken US
Ebbers, Tino (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Fysiologiska kliniken US
visa färre...
 (creator_code:org_t)
2013
Engelska.
  • Annan publikation (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate the feasibility of spiral 3D phase contrast MRI for the assessment of velocity, volume flow rate, peak velocity and turbulent kinetic energy in stenotic flow.Materials and Methods: A-stack-of-spirals 3D phase contrast MRI sequence was evaluated in-vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientations and flow rates. Volume flow rate, peak velocity and turbulent kinetic energy (TKE) were computed for both methods. For further validation, the estimated TKE was compared to computational fluid dynamics (CFD) data.Results: The volume flow rate, peak velocity and TKE obtained with spiral 4D flow MRI agreed well with Cartesian data and CFD data. As expected, the short echo time of the spiral sequence resulted in less prominent displacement artifacts compared to the Cartesian sequence. However, both spiral and Cartesian flow rate estimates were sensitive to displacement when the flow was oblique to the encoding directions.Conclusion: Spiral 3D phase contrast MRI appears favorable for the assessment of stenotic flow. The spiral sequence was more than three times faster and less sensitive to displacement artifacts when compared to a conventional Cartesian sequence.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

vet (ämneskategori)
ovr (ämneskategori)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy