SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-107434"
 

Sökning: id:"swepub:oai:DiVA.org:liu-107434" > A Potentiometric Bi...

A Potentiometric Biosensor for the Detection of Notch 3 Using Functionalized ZnO Nanorods

Ibupoto, Zafar Hussain (författare)
Linköpings universitet,Fysik och elektroteknik,Tekniska högskolan
Khun, Kimleang (författare)
Linköpings universitet,Fysik och elektroteknik,Tekniska högskolan
Liu, Xianjie (författare)
Linköpings universitet,Ytors Fysik och Kemi,Tekniska högskolan
visa fler...
Willander, Magnus (författare)
Linköpings universitet,Fysik och elektroteknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
American Scientific Publishers, 2014
2014
Engelska.
Ingår i: Journal of Nanoscience and Nanotechnology. - : American Scientific Publishers. - 1533-4880 .- 1533-4899. ; 14:9, s. 6704-6710
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The notch signalling plays a vital and radical role for the activity of cellular proliferation, differentiation and apoptosis. In this study, for the first time a particular biosensor is developed for the detection of notch 3. ZnO nanorods were fabricated on the gold coated glass substrate by hydrothermal method and afterwards were decorated with the gold nanoparticles by electrodepositing technique. Scanning electron microscopy (SEM) has shown the perpendicular to the substrate growth pattern of ZnO nanorods. X-ray diffraction (XRD) studies showed the c-axis oriented growth direction with wurtzite crystal structure of ZnO nanorods. X-ray Photoelectron Spectroscopy (XPS) and energy dispersive X-ray (EDX) techniques have shown the presence of Zn, O and Au atoms in the prepared functional material. Furthermore, the anti-notch 3 was physically adsorbed on the gold nanoparticles functionalized ZnO nanorods. The developed potentiometric immunosensor has shown response to the wide range of notch 3 molecules. The detected range included 1.00 x 10(-5)-1.50 x 10(0) mu g/mL with a sensitivity of 23.15 +/- 0.31 mV/decade. The analytical parameters including reproducibility, stability, and selectivity were also investigated and the observed results indicate the acceptable performance of the notch 3 biosensor. Moreover, the proposed notch 3 biosensor exhibited a fast response time of 10 s.

Nyckelord

Gold Nanoparticles; ZnO Nanorods; Potentiometric Technique; Immunosensor; Anti-Notch 3; Notch 3 of Human
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy