Comparison of deep brain stimulation systems

Alonso, Fabiola (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,MINT
Wårdell, Karin (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,MINT
 (creator_code:org_t)
2014-06-06
2014
Engelska.
Ingår i: Poster Presentations. - : Wiley. ; , s. 1173-1173
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Objective: To quantitatively compare the electric field generated by voltage and current controlled deep brain stimulation systems.Background: Traditionally deep brain stimulation (DBS) systems have used voltage control however more recently, current controlled systems have been approved to treat Parkinson's disease and related movement disorders. In the endeavor of understanding the behavior of DBS systems a common approach is the use of computer models suitable to simulate the electric field, current density and other related electric parameters.Methods: 2D finite element models based on commercially available DBS systems have been built for each system: I. Model 3389, Medtronic Inc., USA for voltage control; and II. Model 6142, St Jude Medical Inc. USA for current control. The brain tissue has been simplified to homogeneous and isotropic medium. The electric settings correspond to a monopolar configuration, using one of the four contacts available as the active electrode and the outer boundary of the tissue as the reference. Three simulations were performed to mimic different stages of the leads implantation: a) an original stage where the brain tissue is considered as pure gray matter, b) an acute stage that simulates the leakage of cerebral spinal fluid immediately after the electrodes' insertion; and c) a chronic stage mimicking fibrous tissue created around the electrodes some weeks after implantation. Both systems were submitted to the same conditions using as active electrode the third contact from the tip of the lead. The comparison is based on the maximal distance reached by the isopotential of 0.2 V/mm.Results: The simulations showed that voltage controlled stimulation systems are more susceptible to changes in the electrical conductivity of the medium i.e. change over time of the tissue around the electrode. This agrees with the adjustment of the stimulation amplitude often necessary a few weeks postoperatively. Current controlled stimulation in turn, presented a linear behavior of the distance reached at different stimulation amplitudes at all stages.Conclusions: Current controlled stimulation might be a good option due to its linear behavior over time, nevertheless more studies including a more realistic brain model, different designs of DBS electrodes and different electric parameter, are needed to encourage the use of this type of systems.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Alonso, Fabiola
Wårdell, Karin
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
Artiklar i publikationen
Movement Disorde ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy