SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-107824"
 

Sökning: id:"swepub:oai:DiVA.org:liu-107824" > LC-QTOF-MS as a sup...

LC-QTOF-MS as a superior strategy to immunoassay for the comprehensive analysis of synthetic cannabinoids in urine

Kronstrand, Robert (författare)
Linköpings universitet,Avdelningen för läkemedelsforskning,Hälsouniversitetet,Department of Forensic Genetics and Forensic Toxicology, National Board of Forensic Medicine, Linköping, Sweden
Brinkhagen, Linda (författare)
National Board for Forensic Medicine, Linkoping, Sweden
Birath-Karlsson, Carolina (författare)
National Board for Forensic Medicine, Linkoping, Sweden
visa fler...
Roman, Markus (författare)
National Board for Forensic Medicine, Linkoping, Sweden
Josefsson, Martin (författare)
Linköpings universitet,Kemi,Tekniska högskolan,Department of Forensic Genetics and Forensic Toxicology, National Board of Forensic Medicine, Linköping, Sweden
visa färre...
 (creator_code:org_t)
2014-01-15
2014
Engelska.
Ingår i: Analytical and Bioanalytical Chemistry. - : Springer Verlag (Germany). - 1618-2642 .- 1618-2650. ; 406:15, s. 3599-3609
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objective of this study was to compare the performance of an immunoassay screening for synthetic cannabinoids with a newly developed confirmation method using liquid chromatography quadrupole time-of-flight mass spectrometry. The screening included metabolites from JWH-018, JWH-073, and AM-2201. The confirmation included metabolites from AM-2201, JWH-018, JWH-019, JWH-073, JWH-081, JWH-122, JWH-210, JWH-250, JWH-398, MAM-2201, RCS-4, and UR-144. The immunoassay was tested and found to have no cross-reactivity with UR-144 metabolites but considerable cross-reactivity with MAM-2201 and JWH-122 metabolites. Sensitivity and specificity for the immunoassay were evaluated with 87 authentic urine samples and found to be 87 % and 82 %, respectively. With a cutoff at 2 ng/ml, the confirmation showed 80 positive findings in 38 cases. The most common finding was JWH-122 5-OH-pentyl, followed by JWH-018 5-OH-pentyl. There were 9 findings of UR-144 metabolites and 3 of JWH-073 metabolites. In summary, the immunoassay performed well, presenting both high sensitivity and specificity for the synthetic cannabinoids present in the urine samples tested. The rapid exchange of one cannabinoid for another may pose problems for immunoassays as well as for confirmation methods. However, we consider time-of-flight mass spectrometry to be superior since new metabolites can be quickly included and identified.

Nyckelord

LC-Q-TOF; Synthetic cannabinoids; Immunoassay; Metabolites; Forensic
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy