SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-109934"
 

Sökning: id:"swepub:oai:DiVA.org:liu-109934" > Single crystal sili...

Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

Torrisi, Lorenzo (författare)
University of Messina, Italy
Foti, Gaetano (författare)
University of Catania, Italy
Giuffrida, Lorenzo (författare)
University of Messina, Italy
visa fler...
Puglisi, Donatella (författare)
University of Catania, Italy
Wolowski, J. (författare)
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Badziak, J. (författare)
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Parys, P. (författare)
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Rosinski, M. (författare)
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Margarone, Daniele (författare)
Institute of Physics, ASCR, Prague, Czech Republic
Krasa, J. (författare)
Institute of Physics, ASCR, Prague, Czech Republic
Velyhan, A. (författare)
Institute of Physics, ASCR, Prague, Czech Republic
Ullschmied, U. (författare)
Institute of Physics, ASCR, Prague, Czech Republic
visa färre...
 (creator_code:org_t)
American Institute of Physics (AIP), 2009
2009
Engelska.
Ingår i: Journal of Applied Physics. - : American Institute of Physics (AIP). - 0021-8979 .- 1089-7550. ; 105, s. 123304-1-123304-7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A single-crystal silicon carbide SiC detector was used for measurements of soft x rays, electrons, and ion emission from laser-generated plasma obtained with the use of the Prague Asterix Laser System PALS at intensities of the order of 1016 W/cm2 and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the nature of the irradiated target. The spectra obtained by using the SiC detector show not only the photopeak due to UV and softx-ray detection, but also various peaks due to the detection of energetic charged particles. Time-of-flight technique was employed to determine the ion kinetic energy of particles emitted from the plasma and to perform a comparison between SiC and traditional ion collectors. The detector was also employed by inserting absorber films of different thickness in front of the SiC surface inorder to determine, as a first approximation, the mean energy of the soft x-ray emission from the plasma.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Silicon carbide
x-ray detector
laser
plasma
time of flight

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy