Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device

Al-Karkhi, Isam (författare)
Linköpings universitet,Avdelningen för samhällsmedicin,Medicinska fakulteten
Al-Rubaiy, Raad (författare)
Linköpings universitet,Avdelningen för samhällsmedicin,Medicinska fakulteten
Rosenqvist, Ulf (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Medicinska specialistkliniken
visa fler...
Falk, Magnus (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för samhällsmedicin,Hälsouniversitetet,Primärvården i centrala länsdelen,Forsknings- och utvecklingsenheten för Närsjukvården i Östergötland
Nyström, Fredrik H (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Endokrinmedicinska kliniken
visa färre...
 (creator_code:org_t)
Lippincott Williams & Wilkins, 2015
2015
Engelska.
Ingår i: Blood Pressure Monitoring. - : Lippincott Williams & Wilkins. - 1359-5237 .- 1473-5725. ; 20:2, s. 98-103
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: We aimed to compare blood pressure (BP) levels recorded using the semiautomatic oscillometric Omron i-C10 BP device in patients with or without hypertension in three different settings: (a) when used by a doctor or a nurse at the office (OBP); (b) when used for self-measurement by the patient at the office (SMOBP); and (c) when used for 7 consecutive days at home (HBP).MATERIALS AND METHODS: A total of 247 individuals were invited to participate, but 78 of these individuals declined and a further seven were excluded, leaving a final cohort of 162 participants.RESULTS: The mean OBP was higher than HBP (difference 8.1±14/3.1±8.8 mmHg, P<0.0001) and so was SMOBP compared with HBP (difference 7.0±13/4.2±7.3 mmHg, P<0.0001). Sixteen participants (9.9%) had at least 10 mmHg higher systolic SMOBP than OBP and 28 (17%) participants had at least 10 mmHg lower systolic SMOBP than OBP. Participants who were current smokers had a larger mean difference between systolic OBP and SMOBP than nonsmokers (OBP-SMOBP in smokers: 6.6±9.4 mmHg, OBP-SMOBP in nonsmokers: 0.5±9.2 mmHg, P=0.011 between groups).CONCLUSION: Self-measurement of BP in the office does not preclude an increase in BP when levels in the individual patients are compared with HBP using the same equipment. Thus, SMOBP with a semiautomatic device does not lead to a reduction in the white-coat effect in the same manner as fully automatic devices.This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/3.0.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

home blood pressure; hypertension; office blood pressure; oscillometric; smoking.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Al-Karkhi, Isam
Al-Rubaiy, Raad
Rosenqvist, Ulf
Falk, Magnus
Nyström, Fredrik ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Blood Pressure M ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy