Assessment of shoulder acitve range of motion in prone versus supine : a reliability and concurrent validity study

Furness, James (författare)
Bond Institute of Health and Sport, Bond University, Gold Coast, Queensland, Australia
Johnstone, Scott (författare)
Bond Institute of Health and Sport, Bond University, Gold Coast, Queensland, Australia
Hing, Wayne (författare)
Bond Institute of Health and Sport, Bond University, Gold Coast, Queensland, Australia
visa fler...
Abbott, Allan (författare)
Bond Institute of Health and Sport, Bond University, Gold Coast, Queensland, Australia
Climstein, Mike (författare)
Bond Institute of Health and Sport, Bond University, Gold Coast, Queensland, Australia
visa färre...
 (creator_code:org_t)
2015-09-11
2015
Engelska.
Ingår i: Physiotherapy Theory and Practice. - : Taylor & Francis Group. - 0959-3985 .- 1532-5040. ; 31:7, s. 489-495
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: As swimming and surfing are prone dominant sports, it would be more sport specific to assess shoulder active range of motion in this position. Objectives: To determine the reliability of the inclinometer and HALO© for assessing shoulder active range of motion in supine and prone and the concurrent validity of the HALO©. Concurrent validity is based on the comparison of the HALO© and inclinometer. To determine if active range of motion (AROM) differences exists between prone and supine when assessing shoulder internal (IR) and external rotation (ER). Design: The design included clinical measurement, reliability and validity. Methods: Thirty shoulders (mean age = 26.8 years) without pathology were evaluated. Measurements were taken in supine and prone with both an inclinometer and HALO© device. Results: Active ER ROM in prone was significantly higher than in supine when using both devices. Intra-rater reliability (within and between session) intraclass correlation coefficient (ICC) values ranged between 0.82–0.99 for both devices in supine and prone. An ICC test revealed a significant (p < 0.01) correlation for both devices in IR and ER movements (ICC3,1 = 0.87 and ICC3,1 = 0.72), respectively. Conclusion: This study has shown prone assessment of active ER and IR ROM to be a reliable and appropriate method for prone dominant athletes (swimmers and surfers). In this study greater ER ROM was achieved in prone compared to supine. This finding highlights the importance of standardizing the test position for initial and follow up assessments. Furthermore the HALO© and inclinometer have been shown to be reliable tools that show good concurrent validity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Nyckelord

Inclinometer
prone
range of motion
reliability
shoulder

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Furness, James
Johnstone, Scott
Hing, Wayne
Abbott, Allan
Climstein, Mike
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
Artiklar i publikationen
Physiotherapy Th ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy