An Optical Method for Serum Calcium and Phosphorus Level Assessment during Hemodialysis

Holmar, Jana (författare)
Tallin University of Technology, Tallin, Estonia
Uhlin, Fredrik (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Njurmedicinska kliniken US
Fernström, Anders (författare)
Linköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, Njurmedicinska kliniken US
visa fler...
Luman, Merike (författare)
Tallin University of Technology, North Estonian Medical Centre, Tallin, Estonia
Jankowski, Joachim (författare)
Aachen University , University Hospital Aachen, Germany
Fridolin, Ivo (författare)
Tallin University of Technology, Tallin, Estonia
visa färre...
 (creator_code:org_t)
2015-02-27
2015
Engelska.
Ingår i: Toxins. - BASEL, SWITZERLAND : MDPI AG. - 2072-6651. ; 7:3, s. 719-727
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Survival among hemodialysis patients is disturbingly low, partly because vascular calcification (VC) and cardiovascular disease are highly prevalent. Elevated serum phosphorus (P) and calcium (Ca) levels play an essential role in the formation of VC events. The purpose of the current study was to reveal optical monitoring possibilities of serum P and Ca values during dialysis. Twenty-eight patients from Tallinn (Estonia) and Linköping (Sweden) were included in the study. The serum levels of Ca and P on the basis of optical information, i.e., absorbance and fluorescence of the spent dialysate (optical method) were assessed. Obtained levels were compared in means and SD. The mean serum level of Ca was 2.54 ± 0.21 and 2.53 ± 0.19 mmol/L; P levels varied between 1.08 ± 0.51 and 1.08 ± 0.48 mmol/L, measured in the laboratory and estimated by the optical method respectively. The levels achieved were not significantly different (p = 0.5). The Bland-Altman 95% limits of agreement between the two methods varied from -0.19 to 0.19 for Ca and from -0.37 to 0.37 in the case of P. In conclusion, optical monitoring of the spent dialysate for assessing the serum levels of Ca and P during dialysis seems to be feasible and could offer valuable and continuous information to medical staff.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Hälso- och sjukvårdsorganisation, hälsopolitik och hälsoekonomi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Health Care Service and Management, Health Policy and Services and Health Economy (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Toxins (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy