SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-123681"
 

Sökning: id:"swepub:oai:DiVA.org:liu-123681" > Creatinine and urea...

Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite

Zhybak, M.T. (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska fakulteten,Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Kyiv, Ukraine
Beni, Valerio (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska fakulteten
Vagin, Mikhail (författare)
Linköpings universitet,Kemiska och optiska sensorsystem,Tekniska fakulteten
visa fler...
Dempsey, Eithne (författare)
Centre for Research in Electroanalytical Technologies, Department of Science, ITT Dublin, Tallaght, Dublin, Ireland
Turner, Anthony, 1950- (författare)
Linköpings universitet,Biosensorer och bioelektronik,Tekniska fakulteten
Korpan, Y (författare)
Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine,Kyiv, Ukraine
visa färre...
 (creator_code:org_t)
Elsevier, 2016
2016
Engelska.
Ingår i: Biosensors & bioelectronics. - : Elsevier. - 0956-5663 .- 1873-4235. ; 77, s. 505-511
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of a novel ammonium ion-specific copper-polyaniline nano-composite as transducer for hydrolase-based biosensors is proposed. In this work, a combination of creatinine deaminase and urease has been chosen as a model system to demonstrate the construction of urea and creatinine biosensors to illustrate the principle. Immobilisation of enzymes was shown to be a crucial step in the development of the biosensors; the use of glycerol and lactitol as stabilisers resulted in a significant improvement, especially in the case of the creatinine, of the operational stability of the biosensors (from few hours to at least 3 days). The developed biosensors exhibited high selectivity towards creatinine and urea. The sensitivity was found to be 85±3.4 mA M−1 cm−2 for the creatinine biosensor and 112±3.36 mA M−1 cm−2 for the urea biosensor, with apparent Michaelis–Menten constants (KM,app), obtained from the creatinine and urea calibration curves, of 0.163 mM for creatinine deaminase and 0.139 mM for urease, respectively. The biosensors responded linearly over the concentration range 1–125 µM, with a limit of detection of 0.5 µM and a response time of 15 s.The performance of the biosensors in a real sample matrix, serum, was evaluated and a good correlation with standard spectrophotometric clinical laboratory techniques was found.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Creatinine; Urea; Amperometric ammonium detection; Copper polyanilinecomposite

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy