Fat Quantification in Skeletal Muscle Using Multigradient-Echo Imaging: Comparison of Fat and Water References

Peterson, Pernilla (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital, Sweden
Romu, Thobias (författare)
Linköpings universitet,Medicinsk informatik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Brorson, Håkan (författare)
Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups,Lund University, Sweden
visa fler...
Dahlqvist Leinhard, Olof (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Radiofysikavdelningen US
Månsson, Sven (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital, Sweden
visa färre...
 (creator_code:org_t)
2015-06-10
2016
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY-BLACKWELL. - 1053-1807 .- 1522-2586. ; 43:1, s. 203-212
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To investigate the precision, accuracy, and repeatability of water/fat imaging-based fat quantification in muscle tissue using a large flip angle (FA) and a fat reference for the calculation of the proton density fat fraction (FF). Comparison is made to a small FA water reference approach. Materials and Methods: An Intralipid phantom and both forearms of six patients suffering from lymphedema and 10 healthy volunteers were investigated at 1.5T. Two multigradient-echo sequences with eight echo times and FAs of 10 degrees and 85 degrees were acquired. For healthy volunteers, the acquisition of the right arm was performed twice with repositioning. From each set, water reference FF and fat reference FF images were reconstructed and the average FF and the standard deviation were calculated within the subfascial compartment. The small FA water reference was considered the reference standard. Results: A high agreement was found between the small FA water reference and large FA fat reference methods (FF bias=0.31%). In this study, the large FA fat reference approach also resulted in higher precision (38% smaller FF standard deviation in homogenous muscle tissue), but no significant difference in repeatability between the various methods was detected (coefficient of repeatability of small FA water reference approach 0.41%). Conclusion: The precision of fat quantification in muscle tissue can be increased with maintained accuracy using a larger flip angle, if a fat reference instead of a water reference is used.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

fat quantification; water; fat imaging; skeletal muscle; water reference; internal fat reference

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy