SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-13008"
 

Sökning: id:"swepub:oai:DiVA.org:liu-13008" > Fibre-optic array f...

Fibre-optic array for curvature assessment : application in otitis diagnosis

Sundberg, Mikael (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Borga, Magnus (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan
Knutsson, Hans (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan
visa fler...
Johansson, Anders (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Strömberg, Tomas (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Öberg, Åke (författare)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
2004
2004
Engelska.
Ingår i: Medical & Biological Engineering & Computing. - 0140-0118. ; 42:2, s. 245-252
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A contact-free sensor consisting of two parallel optical-fibre arrays was designed to assess surface shapes of diffusely scattering media. By sequentially illuminating objects using one fibre array and detecting the diffusely back-scattered photons by the other, a source-detector intensity matrix was formed, where the matrix element (i, j) was the intensity at detector j when light source i was excited. Experimental data from convex and concave polyacetal plastic surfaces were recorded. A mathematical model was used for simulating source-detector intensity matrices for the surfaces analysed in the experiments. Experimental results from the system were compared with the theoretically expected results provided by the mathematical model. The shape and relative amplitude showed similar behaviour in the experiments and simulations. A convex/concave discriminator index D, representing the detected intensity difference between two source-detector separations, was defined. The relative dynamic range of D, defined as the difference between the maximum and the minimum divided by the mean of the index, was 1.37 for convex surfaces and 0.68 for concave surfaces, at a measuring distance of 4.5mm. The index D was positive for convex surfaces and negative for concave surfaces, which showed that the system could distinguish between convex and concave surfaces, an important result for the diagnosis of otitis media.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Diffuse reflection
Optical imaging
Otitis media
Surface shape identification
Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy