SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-13167"
 

Sökning: id:"swepub:oai:DiVA.org:liu-13167" > The effect of gamma...

The effect of gamma irradiation on the quality of apheresis platelets during storage for 7 days

Tynngård, Nahreen (författare)
Linköpings universitet,Transfusionsmedicin,Hälsouniversitetet
Studer, Monika (författare)
University Hospital, Linköping, Sweden
Lindahl, Tomas L (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
visa fler...
Trinks, Marie (författare)
University Hospital, Linköping, Sweden
Berlin, Gösta (författare)
Linköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Wiley, 2008
2008
Engelska.
Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 48:8, s. 1669-1675
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background:This study compares the quality of gamma-irradiated versus nonirradiated platelet (PLT) concentrates (PCs) during storage for 7 days as assessed by various in vitro methods. A new technique, free oscillation rheometry (FOR), which measures clotting time and coagulum elasticity, was also used to evaluate the PLT function. Study design and methods: Single-donor PLTs were collected by apheresis technique (n = 20). The PLTs from each donor were divided into two PCs, one gamma-irradiated with 25 Gy and the other used as a nonirradiated control. Blood gases, metabolic variables, and swirling were analyzed from Day 0. Samples taken on Days 1, 5, and 7 were also analyzed for hypotonic shock response (HSR), P-selectin, and glycoprotein (GP)Ib expression by flow cytometry and coagulation by FOR. Results: Swirling, HSR, and the percentage of GPIb-expressing cells were well maintained for 7 days of storage. pH was always within accepted range (6.4-7.4). Glucose decreased and lactate increased during the storage period (p < 0.05). P-selectin expression increased during storage (p < 0.05). The FOR clotting time remained constant, whereas the build-up of elasticity was slower after storage (p < 0.05). No difference was found between irradiated and nonirradiated PCs. Conclusion: The results indicate a well-preserved quality of gamma-irradiated apheresis PLTs during storage for 7 days as assessed by in vitro methods, with no difference compared to nonirradiated PLTs.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy