Assessment of turbulent viscous stress using ICOSA 4D Flow MRI for prediction of hemodynamic blood damage

Ha, Hojin (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten
Lantz, Jonas (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten
Haraldsson, Henrik (författare)
University of Calif San Francisco, CA 94143 USA
visa fler...
Casas Garcia, Belén (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten
Ziegler, Magnus (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten
Karlsson, Matts (författare)
Linköpings universitet,Mekanisk värmeteori och strömningslära,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Saloner, David (författare)
University of Calif San Francisco, CA 94143 USA
Dyverfeldt, Petter (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Ebbers, Tino (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
visa färre...
 (creator_code:org_t)
2016-12-22
2016
Engelska.
Ingår i: SCIENTIFIC REPORTS. - : NATURE PUBLISHING GROUP. - 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Flow-induced blood damage plays an important role in determining the hemodynamic impact of abnormal blood flow, but quantifying of these effects, which are dominated by shear stresses in highly fluctuating turbulent flow, has not been feasible. This study evaluated the novel application of turbulence tensor measurements using simulated 4D Flow MRI data with six-directional velocity encoding for assessing hemodynamic stresses and corresponding blood damage index (BDI) in stenotic turbulent blood flow. The results showed that 4D Flow MRI underestimates the maximum principal shear stress of laminar viscous stress (PLVS), and overestimates the maximum principal shear stress of Reynolds stress (PRSS) with increasing voxel size. PLVS and PRSS were also overestimated by about 1.2 and 4.6 times at medium signal to noise ratio (SNR) = 20. In contrast, the square sum of the turbulent viscous shear stress (TVSS), which is used for blood damage index (BDI) estimation, was not severely affected by SNR and voxel size. The square sum of TVSS and the BDI at SNR amp;gt;20 were underestimated by less than 1% and 10%, respectively. In conclusion, this study demonstrated the feasibility of 4D Flow MRI based quantification of TVSS and BDI which are closely linked to blood damage.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy