Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate

Uhlin, Fredrik (författare)
Linköpings universitet,Njurmedicin,Hälsouniversitetet
Fridolin, Ivo (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Lindberg, Lars-Göran (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
visa fler...
Magnusson, Martin (författare)
Linköpings universitet,Njurmedicin,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: American Journal of Kidney Diseases. - 0272-6386 .- 1523-6838. ; 41:5, s. 1026-1036
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background:Several methods are available to determine Kt/V, from predialysis and postdialysis blood samples to using on-line dialysate urea monitors or to ionic dialysance using a conductivity method. The aim of this study is to compare Kt/V calculated from the slope of the logarithmic on-line ultraviolet (UV) absorbance measurements, blood urea Kt/V, dialysate urea Kt/V, and Kt/V from the Urea Monitor 1000 (UM; Baxter Healthcare Corp, Deerfield, IL).Methods:Thirteen uremic patients on chronic thrice-weekly hemodialysis therapy were included in the study. The method uses absorption of UV radiation by means of a spectrophotometric set-up. Measurements were performed on-line with the spectrophotometer connected to the fluid outlet of the dialysis machine; all spent dialysate passed through a specially designed cuvette for optical single-wavelength measurements. UV absorbance measurements were compared with those calculated using blood urea and dialysate urea, and, in a subset of treatments, the UM.Results:Equilibrated Kt/V (eKt/V) obtained with UV absorbance (eKt/Va) was 1.19 ± 0.23; blood urea (eKt/Vb), 1.30 ± 0.20, and dialysate urea (eKt/Vd), 1.26 ± 0.21, and Kt/V in a subset measured by the UM (UM Kt/V) was 1.24 ± 0.18. The difference between eKt/Vb and eKt/Va was 0.10 ± 0.11, showing a variation similar to the difference between eKt/Vb and eKt/Vd (0.03 ± 0.10) and in a subset between eKt/Vb and UM Kt/V (−0.02 ± 0.11).Conclusion:The study suggests that urea Kt/V can be estimated by on-line measurement of UV absorption in the spent dialysate.

Nyckelord

Hemodialysis (HD)
dialysis monitoring
dialysis dose
spectrophotometry
absorption
ultraviolet (UV)
solute removal
spent dialysate
dialysis adequacy
dialysis efficiency
urea
Kt/V
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy