A cool response : the influence of ambient temperature on capillary refill time

Toll John, Rani, 1975- (författare)
Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Akutkliniken i Linköping
Henricson, Joakim, 1977- (författare)
Linköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, Akutkliniken i Linköping
Junker, Johan, 1980- (författare)
Linköpings universitet,Avdelningen för Kirurgi, Ortopedi och Onkologi,Medicinska fakulteten,Region Östergötland, Katastrofmedicinskt centrum
visa fler...
Jonson, Carl-Oscar, Docent, 1978- (författare)
Linköpings universitet,Medicinska fakulteten,Avdelningen för Kirurgi, Ortopedi och Onkologi,Region Östergötland, Katastrofmedicinskt centrum
Nilsson, Gert, 1947- (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,WheelsBridge AB, Linköping, Sweden
Björk Wilhelms, Daniel, 1984- (författare)
Linköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, Akutkliniken i Linköping
Anderson, Chris D, 1949- (författare)
Linköpings universitet,Avdelningen för cellbiologi,Medicinska fakulteten,Region Östergötland, Hudkliniken i Östergötland
visa färre...
 (creator_code:org_t)
2018-03-05
2018
Engelska.
Ingår i: Journal of Biophotonics. - : Wiley-VCH Verlagsgesellschaft. - 1864-063X .- 1864-0648. ; 11:6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ObjectiveTo describe the effect of low ambient temperature on skin temperature and capillary refill (CR) time in forehead, sternum and finger pulp.MethodsAn observational, nonrandomized experimental study on 15 healthy subjects (6 females) in a cold room (8°C). Outcome measures were skin temperature and quantified CR test after application of a standardized blanching pressure (9 N/cm2) using digital photographic polarization spectroscopy to generate CR times.ResultsThe finger pulp showed marked temperature fall and prolonged CR times (>10 seconds). The CR registrations of the forehead and sternum were more comparable to curves observed in a control material at room temperature, and skin temperature falls were less marked. CR times were not prolonged in forehead measurements. At the sternum, some individuals showed CR times beyond guideline recommendations despite only a marginal reduction in skin temperature.ConclusionsLow ambient temperature is a strong independent factor for CR time at peripheral sites. Reservation about sternum as a site of measurement is warranted since cold provocation produced prolonged CR times in some individuals. We found that the forehead is the most thermostable of the 3 sites and thus the preferred site to avoid ambient temperature artifact in measuring CR time.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Disaster Medicine
Katastrofmedicin

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy