SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-14555"
 

Sökning: id:"swepub:oai:DiVA.org:liu-14555" > Pitfalls in Doppler...

Pitfalls in Doppler evaluation of diastolic function : insights from 3-dimensional magnetic resonance imaging

Fyrenius, Anna (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
Wigström, Lars (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
Bolger, Ann F. (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
visa fler...
Ebbers, Tino (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken
Öhman, Peter (författare)
Linköpings universitet,Internmedicin,Hälsouniversitetet
Karlsson, Matts (författare)
Linköpings universitet,Biomedicinsk modellering och simulering,Tekniska högskolan
Wranne, Bengt (författare)
Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken
Engvall, Jan (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Amsterdam : Elsevier Science B.V. 1999
1999
Engelska.
Ingår i: Journal of the American Society of Echocardiography. - Amsterdam : Elsevier Science B.V.. - 0894-7317 .- 1097-6795. ; 12:10, s. 817-826
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ultrasound-Doppler assessment of diastolic function is subject to velocity errors caused by angle sensitivity and a fixed location of the sample volume. We used 3-dimensional phase contrast magnetic resonance imaging (MRI) to evaluate these errors in 10 patients with hypertension and in 10 healthy volunteers. The single (Doppler) and triple (MRI) component velocity was measured at early (E) and late (A) inflow along Doppler-like sample lines or 3-dimensional particle traces generated from the MRI data. Doppler measurements underestimated MRI velocities by 9.4% ± 8.6%; the effect on the E/A ratio was larger and more variable. Measuring early and late diastolic inflows from a single line demonstrated the error caused by their 3-dimensional spatial offset. Both errors were minimized by calculating the E/A ratio from maximal E and A values without constraint to a single line. Alignment and spatial offset are important sources of error in Doppler diastolic parameters. Improved accuracy may be achieved with the use of maximal E and A velocities from wherever they occur in the left ventricle.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy