SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-152299"
 

Sökning: id:"swepub:oai:DiVA.org:liu-152299" > Method using in viv...

Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices : emulation and evaluation of multispectral imaging systems

Saager, Rolf B., 1974- (författare)
Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
Baldado, Melissa L. (författare)
Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
Rowland, Rebecca A. (författare)
Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
visa fler...
Kelly, Kristen M. (författare)
Beckman Laser Institute and Medical Clinic, USA
Durkin, Anthony J. (författare)
Beckman Laser Institute and Medical Clinic, USA
visa färre...
Beckman Laser Institute and Medical Clinic, Univ of California, Irvine, USA Beckman Laser Institute and Medical Clinic, USA (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2018
2018
Engelska.
Ingår i: Journal of Biomedical Optics. - : SPIE - International Society for Optical Engineering. - 1083-3668 .- 1560-2281. ; 23:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • With recent proliferation in compact and/or low-cost clinical multispectral imaging approaches and commercially available components, questions remain whether they adequately capture the requisite spectral content of their applications. We present a method to emulate the spectral range and resolution of a variety of multispectral imagers, based on in-vivo data acquired from spatial frequency domain spectroscopy (SFDS). This approach simulates spectral responses over 400 to 1100 nm. Comparing emulated data with full SFDS spectra of in-vivo tissue affords the opportunity to evaluate whether the sparse spectral content of these imagers can (1) account for all sources of optical contrast present (completeness) and (2) robustly separate and quantify sources of optical contrast (crosstalk). We validate the approach over a range of tissue-simulating phantoms, comparing the SFDS-based emulated spectra against measurements from an independently characterized multispectral imager. Emulated results match the imager across all phantoms (<3  %   absorption, <1  %   reduced scattering). In-vivo test cases (burn wounds and photoaging) illustrate how SFDS can be used to evaluate different multispectral imagers. This approach provides an in-vivo measurement method to evaluate the performance of multispectral imagers specific to their targeted clinical applications and can assist in the design and optimization of new spectral imaging devices.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy