SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-156909"
 

Sökning: id:"swepub:oai:DiVA.org:liu-156909" > Calibration and Cha...

Calibration and Characterization of a Magnetic Positioning System Using a Robotic Arm

Santoni, Francesco (författare)
Univ Perugia, Italy
De Angelis, Alessio (författare)
Univ Perugia, Italy
Skog, Isaac (författare)
Linköpings universitet,Reglerteknik,Tekniska fakulteten
visa fler...
Moschitta, Antonio (författare)
Univ Perugia, Italy
Carbone, Paolo (författare)
Univ Perugia, Italy
visa färre...
 (creator_code:org_t)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2019
2019
Engelska.
Ingår i: IEEE Transactions on Instrumentation and Measurement. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0018-9456 .- 1557-9662. ; 68:5, s. 1494-1502
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, a robotic arm moving along a user-defined trajectory is used to calibrate a short-range magnetic positioning system (MPS). Such system estimates the position and attitude of an active transmitting coil by measuring the induced voltage on a set of fixed receiving coils, with known position and orientation. This estimate is obtained by solving an optimization problem that can be decomposed into a linear and a reduced nonlinear problem. Then, a Kalman Filter is used to process the estimated positions and obtain smooth trajectories. Data acquisition and processing are performed in real time by the MPS. In this context, the robotic arm is used to provide ground truth, i.e., to move the active coil along a known trajectory, while simultaneously the MPS estimates the position of the active coil. Such ground-truth information is then used to calibrate the MPS and improve its accuracy. To align the robotic arm with the MPS, a preliminary calibration procedure of the robot is performed. Then, a wide ground-truth trajectory is used to estimate the calibration parameters of the MPS itself, namely, the positions and orientation of the fixed coils. To validate the efficiency of the calibration procedure, the accuracy of the MPS is evaluated across several trajectories. The results show that the mean positioning error is less than 3 mm. Finally, an on-the-fly calibration method simultaneously estimating positions and attitudes of both the active coil and all the receivers is investigated.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)

Nyckelord

Distance measurement; magnetic fields; positioning; resonators; tracking

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy