SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-156927"
 

Sökning: id:"swepub:oai:DiVA.org:liu-156927" > Carbon quantum dot ...

Carbon quantum dot coated Fe3O4 hybrid composites for sensitive electrochemical detection of uric acid

Abbas, Malik Waseem (författare)
Natl Inst Biotechnol and Genet Engn, Pakistan
Soomro, Razium Ali (författare)
Natl Inst Biotechnol and Genet Engn, Pakistan; Univ Sindh, Pakistan; Univ Bristol, England
Kalwar, Nazar Hussain (författare)
Shah Abdul Latif Univ, Pakistan
visa fler...
Zahoor, Mehvish (författare)
Natl Inst Biotechnol and Genet Engn, Pakistan
Avci, Ahmet (författare)
Selcuk Univ, Turkey
Pehlivan, Erol (författare)
Selcuk Univ, Turkey
Hallam, Keith Richard (författare)
Univ Bristol, England
Willander, Magnus (författare)
Linköpings universitet,Fysik, elektroteknik och matematik,Tekniska fakulteten
visa färre...
 (creator_code:org_t)
ELSEVIER SCIENCE BV, 2019
2019
Engelska.
Ingår i: Microchemical journal (Print). - : ELSEVIER SCIENCE BV. - 0026-265X .- 1095-9149. ; 146, s. 517-524
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The study explores carbon quantum dots (C-dots) as potential candidates for enhancing the signal sensitivity of an electrochemical sensor devised for biologically important molecule, such as uric acid (UA). The C-dots were evaluated for their electrochemical characteristics in combination with Fe3O4 nanoparticles (Fe3O4 NPs), which were applied as the primary electro-catalytic promoter. The hybrid nanocomposite (C-dots/Fe3O4 HCs) formation was achieved by facilitating the adsorption of C-dots over Fe3O4 NPs using amine-carbonyl interactions. Unlike, one pot method, the proposed strategy enables aggregation-free coverage of Fe3O4 NPs with highly conductive layer of C-dots that can act as conduction centres to support ultra-fast electron transfer kinetics to satisfy the need of high signal sensitivity. The hybrid composite demonstrated remarkable signal improvement when tested against the electrochemical oxidation of UA. The heighten current response and lower over-potential values enabled development of a DC-amperometric (DC-AMP) sensor for UA with a linear working range of 0.01 to 0.145 mu M and signal sensitivity measurable up to 6.0 x 10(-9) M. The said improvement was manifested as a synergetic outcome of active redox couple (Fe (III/II)), larger surface area of Fe3O4 NPs engulfed with a layer of highly conductive C-dots acting as efficient charge sensitisers.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Polymerteknologi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Polymer Technologies (hsv//eng)

Nyckelord

C-dots; Magnetite NPs; Uric acid; Electrochemical sensors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy