Testing the methodology for a dosimetric end-to-end audit of IMRT/VMAT: results of IAEA multicentre and national studies

Wesolowska, Paulina (författare)
IAEA, Austria
Georg, Dietmar (författare)
Med Univ Vienna, Austria; Christian Doppler Lab Med Radiat Res Radiat Oncol, Austria
Lechner, Wolfgang (författare)
Med Univ Vienna, Austria; Christian Doppler Lab Med Radiat Res Radiat Oncol, Austria
visa fler...
Kazantsev, Pavel (författare)
IAEA, Austria
Bokulic, Tomislav (författare)
IAEA, Austria
Carlsson Tedgren, Åsa (författare)
Karolinska Institutet,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik,Karolinska Univ Hosp, Sweden
Adolfsson, Emelie (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten
Campos, Anna Maria (författare)
Inst Nacl Canc, Brazil
Leandro Alves, Victor Gabriel (författare)
Inst Nacl Canc, Brazil
Suming, Luo (författare)
Chinese Ctr Dis Control and Prevent, Peoples R China
Hao, Wu (författare)
Beijing Canc Hosp, Peoples R China
Ekendahl, Daniela (författare)
Natl Radiat Protect Inst, Czech Republic
Koniarova, Irena (författare)
Natl Radiat Protect Inst, Czech Republic
Bulski, Wojciech (författare)
Maria Sklodowska Curie Mem Canc Ctr and Inst Oncol, Poland
Chelminski, Krzysztof (författare)
Maria Sklodowska Curie Mem Canc Ctr and Inst Oncol, Poland
Alonso Samper, Jose Luis (författare)
Natl Inst Oncol and Radiobiol, Cuba
Vinatha, Sumanth Panyam (författare)
Bhabha Atom Res Ctr Trombay, India
Rakshit, Sougata (författare)
Bhabha Atom Res Ctr Trombay, India
Siri, Srimanoroth (författare)
SSDL, Thailand,Anderson Canc Ctr, TX USA
Tomsejm, Milan (författare)
Hop Andre Vesale, Belgium
Tenhunen, Mikko (författare)
Helsinki Univ Helsinki, Finland
Povall, Julie (författare)
Univ Leeds, England
Kry, Stephen F. (författare)
Anderson Canc Ctr, TX USA
Followill, David S. (författare)
Anderson Canc Ctr, TX USA
Thwaites, David I. (författare)
Univ Leeds, England; Univ Sydney, Australia
Izewska, Joanna (författare)
IAEA, Austria
visa färre...
 (creator_code:org_t)
TAYLOR & FRANCIS LTD, 2019
2019
Engelska.
Ingår i: Acta Oncologica. - : TAYLOR & FRANCIS LTD. - 0284-186X .- 1651-226X. ; 58:12, s. 1731-1739
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: Within an International Atomic Energy Agency (IAEA) co-ordinated research project (CRP), a remote end-to-end dosimetric quality audit for intensity modulated radiation therapy (IMRT)/ volumetric arc therapy (VMAT) was developed to verify the radiotherapy chain including imaging, treatment planning and dose delivery. The methodology as well as the results obtained in a multicentre pilot study and national trial runs conducted in close cooperation with dosimetry audit networks (DANs) of IAEA Member States are presented. Material and methods: A solid polystyrene phantom containing a dosimetry insert with an irregular solid water planning target volume (PTV) and organ at risk (OAR) was designed for this audit. The insert can be preloaded with radiochromic film and four thermoluminescent dosimeters (TLDs). For the audit, radiotherapy centres were asked to scan the phantom, contour the structures, create an IMRT/VMAT treatment plan and irradiate the phantom. The dose prescription was to deliver 4 Gy to the PTV in two fractions and to limit the OAR dose to a maximum of 2.8 Gy. The TLD measured doses and film measured dose distributions were compared with the TPS calculations. Results: Sixteen hospitals from 13 countries and 64 hospitals from 6 countries participated in the multicenter pilot study and in the national runs, respectively. The TLD results for the PTV were all within +/- 5% acceptance limit for the multicentre pilot study, whereas for national runs, 17 participants failed to meet this criterion. All measured doses in the OAR were below the treatment planning constraint. The film analysis identified seven plans in national runs below the 90% passing rate gamma criteria. Conclusion: The results proved that the methodology of the IMRT/VMAT dosimetric end-to-end audit was feasible for its intended purpose, i.e., the phantom design and materials were suitable; the phantom was easy to use and it was robust enough for shipment. Most importantly the audit methodology was capable of identifying suboptimal IMRT/VMAT delivery.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy