SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-165198"
 

Sökning: id:"swepub:oai:DiVA.org:liu-165198" > 3D-Printed Modular ...

3D-Printed Modular Microfluidic Device Enabling Preconcentrating Bacteria and Purifying Bacterial DNA in Blood for Improving the Sensitivity of Molecular Diagnostics

Abafogi, Abdurhaman Teyib (författare)
Sungkyunkwan Univ, South Korea
Kim, Jaewon (författare)
Sungkyunkwan Univ, South Korea
Lee, Jinyeop (författare)
Sungkyunkwan Univ, South Korea
visa fler...
Mohammed, Merem Omer (författare)
Sungkyunkwan Univ, South Korea
van Noort, Danny (författare)
Linköpings universitet,Teknisk biologi,Tekniska fakulteten,Univ Ljubljana, Slovenia; Univ Ingn and Tecnol UTEC, Peru
Park, Sungsu (författare)
Sungkyunkwan Univ, South Korea; Sungkyunkwan Univ, South Korea; Sungkyunkwan Univ, South Korea
visa färre...
 (creator_code:org_t)
2020-02-21
2020
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 20:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Molecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3Dpm mu FD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3Dpm mu FD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.

Ämnesord

NATURVETENSKAP  -- Biologi -- Mikrobiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Microbiology (hsv//eng)

Nyckelord

molecular diagnostics; microfluidic device; bacterial preconcentration; DNA purification; pathogen

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy