Correlation-Based Calibration for Nonlinearity Mismatches in Dual-Channel TIADCs

Liu, Xiangyu (författare)
Natl Univ Def Technol, Peoples R China
Xu, Hui (författare)
Natl Univ Def Technol, Peoples R China
Johansson, Håkan (författare)
Linköpings universitet,Kommunikationssystem,Tekniska fakulteten
visa fler...
Wang, Yinan (författare)
Natl Univ Def Technol, Peoples R China
Li, Nan (författare)
Natl Univ Def Technol, Peoples R China
visa färre...
 (creator_code:org_t)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2020
2020
Engelska.
Ingår i: IEEE Transactions on Circuits and Systems - II - Express Briefs. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1549-7747 .- 1558-3791. ; 67:3, s. 585-589
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Mismatches affect the dynamic performance of time-interleaved analog-to-digital converters (TIADCs). Linear mismatches can be calibrated by many mature methods, but if higher performance is required, nonlinearity mismatches have to be suppressed. The background calibration method based on input-free band (IFB) functions poorly for narrow-band signals. This brief proposes a correlation-based calibration method for nonlinearity mismatches in dual-channel TIADCs which behaves well for both wide-band and narrow-band signals. The output samples are calibrated by reducing the residual distortions which are approximated by multiplying the pseudo distortions and the estimated mismatch coefficients. The pseudo distortions are acquired by using a frequency-shifter, a differentiator, and multipliers. The coefficients which indicate the mismatch strength are estimated by eliminating the cross-correlation of the calibrated output samples and the calibrated pseudo distortions at zero lag. Simulations show that the proposed method can improve the SFDR by dozens of dBc for narrow-band input signals, compared with the IFB method. For the 16-QAM signal, the error vector magnitude improvement over the IFB method is 35.48 dB.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)

Nyckelord

Estimation; Calibration; Nonlinear distortion; Integrated circuit modeling; Buffer storage; Time-interleaved (TI); analog-to-digital converter (ADC); nonlinearity mismatches; calibration; correlation; background estimation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Liu, Xiangyu
Xu, Hui
Johansson, Håkan
Wang, Yinan
Li, Nan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
och Reglerteknik
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy